Toshiba GR-200-5 Instruction Manual
Also see for GR 200 Series: Instruction manualInstruction manualInstruction manualInstruction manualInstruction manual
6F2T0207 (0.01)GRE200 (5,6)- 796 -DEMAND_MANAGEMENT_MV (Function ID: 714081) Element ID of the signal used for each functionMetering item Description Unit Metering on the screen IEC 60870-5-103 IEC 61850 Modbus NoteVab Min Peak minimum of secondary Vab V 4322251050 NA N/A 2232251050 Modbus conversion factor: 10Vab Ave Peak average of secondary Vab V 4322351050 NA N/A 2232351050 Modbus conversion factor: 10Vbc Max Peak maximum of secondary Vbc V 4322151052 NA N/A 2232151052 Modbus conversion factor: 10Vbc Min Peak minimum of secondary Vbc V 4322251052 NA N/A 2232251052 Modbus conversion factor: 10Vbc Ave Peak average of secondary Vbc V 4322351052 NA N/A 2232351052 Modbus conversion factor: 10Vca Max Peak maximum of secondary Vca V 4322151054 NA N/A 2232151054 Modbus conversion factor: 10Vca Min Peak minimum of secondary Vca V 4322251054 NA N/A 2232251054 Modbus conversion factor: 10Vca Ave Peak average of secondary Vca V 4322351054 NA N/A 2232351054 Modbus conversion factor: 10Va Max Peak maximum of secondary Va V 4322141050 NA N/A 2232141050 Modbus conversion factor: 10Va Min Peak minimum of secondary Va V 4322241050 NA N/A 2232241050 Modbus conversion factor: 10Va Ave Peak average of secondary Va V 4322341050 NA N/A 2232341050 Modbus conversion factor: 10Vb Max Peak maximum of secondary Vb V 4322141052 NA N/A 2232141052 Modbus conversion factor: 10Vb Min Peak minimum of secondary Vb V 4322241052 NA N/A 2232241052 Modbus conversion factor: 10Vb Ave Peak average of secondary Vb V 4322341052 NA N/A 2232341052 Modbus conversion factor: 10Vc Max Peak maximum of secondary Vc V 4322141054 NA N/A 2232141054 Modbus conversion factor: 10Vc Min Peak minimum of secondary Vc V 4322241054 NA N/A 2232241054 Modbus conversion factor: 10Vc Ave Peak average of secondary Vc V 4322341054 NA N/A 2232341054 Modbus conversion factor: 10Ve Max Peak maximum of secondary Ve V 4322181056 NA N/A 2232181056 Modbus conversion factor: 10Ve Min Peak minimum of secondary Ve V 4322281056 NA N/A 2232281056 Modbus conversion factor: 10Ve Ave Peak average of secondary Ve V 4322381056 NA N/A 2232381056 Modbus conversion factor: 10Vs Max Peak maximum of secondary Vs V 4322171056 NA N/A 2232171056 Modbus conversion factor: 10Vs Min Peak minimum of secondary Vs V 4322271056 NA N/A 2232271056 Modbus conversion factor: 10Vs Ave Peak average of secondary Vs V 4322371056 NA N/A 2232371056 Modbus conversion factor: 10V1 Max Peak maximum of secondary V1 V 4322161050 NA N/A 2232161050 Modbus conversion factor: 10V1 Min Peak minimum of secondary V1 V 4322261050 NA N/A 2232261050 Modbus conversion factor: 10V1 Ave Peak average of secondary V1 V 4322361050 NA N/A 2232361050 Modbus conversion factor: 10V2 Max Peak maximum of secondary V2 V 4322161052 NA N/A 2232161052 Modbus conversion factor: 10V0 Max Peak maximum of secondary V0 V 4322161056 NA N/A 2232161056 Modbus conversion factor: 10MES_MV (Function ID: 710081) Element ID of the signal used for each functionMetering item Description Unit Metering on the screen IEC 60870-5-103 IEC 61850 Modbus NoteWh+ Wh+ measurement primary tool monitoring Wh 4307A010A8 N/A N/A N/AWh- Wh- measurement primary tool monitoring Wh 4307A110A8 N/A N/A N/Avarh+ varh+ measurement primary tool monitoring varh 4308A210A8 N/A N/A N/Avarh- varh- measurement primary tool monitoring varh 4308A310A8 N/A N/A N/ASIGMA_IY_MV (Function ID: 713081) Element ID of the signal used for each functionMetering item Description Unit Metering on the screen IEC 60870-5-103 IEC 61850 Modbus NoteSIGMA_IY-A SIGMA_IY value(phase-A) tool monitoring - 430A0110A4 N/A N/A N/ASIGMA_IY-B SIGMA_IY value(phase-B) tool monitoring - 430A0210A5 N/A N/A N/ASIGMA_IY-C SIGMA_IY value(phase-C) tool monitoring - 430A0310A6 N/A N/A N/A |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved