Toshiba GR-200-5 Instruction Manual
Also see for GR 200 Series: Instruction manualInstruction manualInstruction manualInstruction manualInstruction manual
6F2T0207 (0.01)GRE200 (5,6)- 83 -2.4.9 SettingSEF_MV (Function ID: 442081)Setting items Range Unit Contents Default NoteSEF1 SEF1-EN Off / On - SEF1 protection enable OffSEF1 Direction SEF1-Dir NonDir / Forward /Reverse - SEF1 selection of protection direction NonPol. SEF1-Angle -90 - 90 deg SEF1 polarizing angle in directional element -45SEF1-Vpol 3.0 V SEF1 polarizing vol. in directional element 3.0RP RP1-EN Off / On - Enabling RP in directional protection OffRP1 0.00 – 100.00 W Threshold of residual power element 0.00SEF1 characteristicSEF1-TimerDT / IEC-NI / IEC-VI /IEC-EI / UK-LTI /IEEE-MI / IEEE-VI /IEEE-EI / US-CO2 /US-CO8 / Original- SEF1 delay type DTDT SEF1 0.001 - 1.000 A SEF1 threshold (in DT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100TSEF1 0.00 - 300.00 s SEF1 operating delay time (in DT mode) 1.00IEC SEF1 0.001 - 1.000 A SEF1 threshold (in IDMT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100SEF1-TMS-IEC 0.010 - 50.000 - SEF1 time multiplier of IEC inverse curve 1.000TSEF1R 0.00 - 300.00 s SEF1 definite time reset delay 0.00UK SEF1 0.001 - 1.000 A SEF1 threshold (in IDMT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100SEF1-TMS-UK 0.010 - 50.000 - SEF1 time multiplier of UK inverse curve 1.000TSEF1R 0.00 - 300.00 s SEF1 definite time reset delay 0.00IEEE SEF1 0.001 - 1.000 A SEF1 threshold (in IDMT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100SEF1-TMS-IEEE 0.010 - 50.000 - SEF1 time multiplier of IEEE inverse curve 1.000Rtimer SEF1-Rtimer DEF / DEP - SEF1 reset delay type of IEEE DEFTSEF1R 0.00 - 300.00 s SEF1 definite time reset delay 0.00SEF1-RTMS-IEEE 0.010 - 50.000 - SEF1 dependent reset time multiplier of IEEEinverse curve 1.000US SEF1 0.001 - 1.000 A SEF1 threshold (in IDMT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100SEF1-TMS-US 0.010 - 50.000 - SEF1 time multiplier of US inverse curve 1.000Rtimer SEF1-Rtimer DEF / DEP - SEF1 reset delay type of US DEFTSEF1R 0.00 - 300.00 s SEF1 definite time reset delay 0.00SEF1-RTMS-US 0.010 - 50.000 - SEF1 dependent reset time multiplier of USinverse curve 1.000ORG SEF1 0.001 - 1.000 A SEF1 threshold (in IDMT mode) 0.010SEF1-DPR 10 - 100 % SEF1 drop-out/pick-up ratio 100SEF1-TMS-ORG 0.010 - 50.000 - SEF1 time multiplier of Original inverse curve 1.000SEF1-Rtimer DEF / DEP - SEF1 reset delay type of ORG DEFRtimer TSEF1R 0.00 - 300.00 s SEF1 definite time reset delay 0.00SEF1-RTMS-ORG 0.010 - 50.000 - SEF1 dependent reset time multiplier ofOriginal inverse curve 1.000SEF1-k 0.00000 - 500.00000 - SEF1 user original curve coefficient 0.00000SEF1-a 0.00000 - 10.00000 - SEF1 user original curve coefficient 0.00000SEF1-c 0.00000 - 10.00000 - SEF1 user original curve coefficient 0.00000SEF1-kr 0.00000 - 500.00000 - SEF1 user original curve coefficient 0.00000SEF1-b 0.00000 - 10.00000 - SEF1 user original curve coefficient 0.00000 |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved