6F2T0207 (0.01)GRE200 (5,6)- 551 -◆ Signal monitoring points in DPOS01DPOS01(Function ID: 512001)Element ID Name Description8003011E7D DPOS01_SLR_CS DPOS01 select release condition signal8303011D02 DPOS01_ST_OFF DPOS01 Normal open state8103011D03 DPOS01_ST_ON DPOS01 Normal close state0003011D95 DPOS01_TMP_02 DPOS01 time reset selected signal(stSeld) for SAS3103011D80 DPOS01_TMP_06 DPOS01 control event data (selected)3103011D81 DPOS01_TMP_07 DPOS01 control event data (select fail)3103011D82 DPOS01_TMP_08 DPOS01 control event data (select release)3103011D83 DPOS01_TMP_09 DPOS01 control event data (execute output on)3103011D84 DPOS01_TMP_10 DPOS01 control event data (execute command ng)3103011D86 DPOS01_TMP_11 DPOS01 control event data (execute fail)0003011F53 DPOS01_TRA DPOS01 travelling info8203011F43 DPOS01_UDF_DET1 DPOS01 Undefined Detected (3 phase concentration data only)0003011FB6 DPOS01A_CNT_SEL DPOS01 A count change selected signal(stSeld) for SAS3203011D24 DPOS01A_CNT_VAL DPOS01 A-phase count value0003011FB7 DPOS01B_CNT_SEL DPOS01 B count change selected signal(stSeld) for SAS3203011D28 DPOS01B_CNT_VAL DPOS01 B-phase count value0003011FB8 DPOS01C_CNT_SEL DPOS01 C count change selected signal(stSeld) for SAS3203011D2C DPOS01C_CNT_VAL DPOS01 C-phase count value◆ Common signal monitoring pointsDPOS01(Function ID: 512001)Element ID Name Description800301EE32 DEV01_CL_COMMAND dev01 close command800301EE33 DEV01_CL_INTERLOCK dev01 close command with interlock bypass800301EE30 DEV01_OP_COMMAND dev01 open command800301EE31 DEV01_OP_INTERLOCK dev01 open command with interlock bypass820301ED50 DPOS01IN_TMP_28 DPOS01IN_TMP_28800301EE53 DPOS01IN_TMP_29 DPOS01IN_TMP_29810301EE54 DPOS01IN_TMP_30 DPOS01IN_TMP_30800301EE61 DPOS01IN_TMP_31 DPOS01IN_TMP_31810301EE62 DPOS01IN_TMP_32 DPOS01IN_TMP_32800301EE55 DPOS01IN_TMP_33 DPOS01IN_TMP_33800301EE56 DPOS01IN_TMP_34 DPOS01IN_TMP_34810301EE57 DPOS01IN_TMP_35 DPOS01IN_TMP_35820301EE5A DPOS01IN_TMP_36 DPOS01IN_TMP_36830301EE5B DPOS01IN_TMP_37 DPOS01IN_TMP_37800301EE65 DPOS01IN_TMP_38 DPOS01IN_TMP_38810301EE66 DPOS01IN_TMP_39 DPOS01IN_TMP_39800301EDDA DPOS01IN_TMP_40 DPOS01IN_TMP_40810301EDDB DPOS01IN_TMP_41 DPOS01IN_TMP_41820301EE5E DPOS01IN_TMP_42 DPOS01IN_TMP_42830301EE5F DPOS01IN_TMP_43 DPOS01IN_TMP_43800301EE69 DPOS01IN_TMP_44 DPOS01IN_TMP_44800301ED5A DPOS01IN_TMP_45 DPOS01IN_TMP_45800301ED77 DPOS01IN_TMP_46 DPOS01IN_TMP_46◆ Mapping points in DPOS01DPOS(Function ID: 512001)Element ID Name Description7003016D08 DEV01_CONTROL_REQ DPOS01 control command received. (Mapping Data) |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved