6F2T0207 (0.01)GRE200 (5,6)- 101 -2.5.7 SettingOCN_MV (Function ID:443081)Setting items Range Unit Contents Default NoteOCN1-EN Off / On - OCN1 protection scheme switch OffOCN2-EN Off / On - OCN2 protection scheme switch OffOCN3-EN Off / On - OCN3 protection scheme switch OffOCN4-EN Off / On - OCN4 protection scheme switch OffOCN1 OCN1-Dir NonDir / Forward /Reverse - OCN1 directional characteristic NonDirFwd/ OCN1-Angle -90 - 90 deg OCN1 directional characteristic angle -45Rev OCN1-Vpol 0.5 - 25.0 V OCN1 polarizing voltage level 3.0OCN1-TimerDT / IEC-NI / IEC-VI /IEC-EI / UK-LTI /IEEE-MI / IEEE-VI /IEEE-EI / US-CO2 /US-CO8 / Original- OCN1 delay type DTDT OCN1 0.02 - 150.00 A OCN1 threshold (in DT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100TOCN1 0.00 - 300.00 s OCN1 operating delay time 1.00IEC OCN1 0.02 - 25.00 A OCN1 threshold (in IDMT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100OCN1-TMS-IEC 0.010 - 50.000 - OCN1 time multiplier of IEC inverse curve 1.000TOCN1R 0.00 - 300.00 s OCN1 definite time reset delay 0.00UK OCN1 0.02 - 25.00 A OCN1 threshold (in IDMT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100OCN1-TMS-UK 0.010 - 50.000 - OCN1 time multiplier of UK inverse curve 1.000TOCN1R 0.00 - 300.00 s OCN1 definite time reset delay 0.00IEEE OCN1 0.02 - 25.00 A OCN1 threshold (in IDMT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100OCN1-TMS-IEEE 0.010 - 50.000 - OCN1 time multiplier of IEEE inverse curve 1.000OCN1-Rtimer DEF / DEP - OCN1 reset delay type of IEEE DEFTOCN1R 0.00 - 300.00 s OCN1 definite time reset delay 0.00OCN1-RTMS-IEEE 0.010 - 50.000 - OCN1 dependent reset time multiplier ofIEEE inverse curve 1.000US OCN1 0.02 - 25.00 A OCN1 threshold (in IDMT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100OCN1-TMS-US 0.010 - 50.000 - OCN1 time multiplier of US inverse curve 1.000OCN1-Rtimer DEF / DEP - OCN1 reset delay type of US DEFTOCN1R 0.00 - 300.00 s OCN1 definite time reset delay 0.00OCN1-RTMS-US 0.010 - 50.000 - OCN1 dependent reset time multiplier of USinverse curve 1.000ORG OCN1 0.02 - 25.00 A OCN1 threshold (in IDMT mode) 0.40OCN1-DPR 10 - 100 % OCN1 drop-out/pick-up ratio 100OCN1-TMS-ORG 0.010 - 50.000 - OCN1 time multiplier of US inverse curve 1.000OCN1-Rtimer DEF / DEP - OCN1 reset delay type of ORG DEFTOCN1R 0.00 - 300.00 s OCN1 definite time reset delay 0.00OCN1-RTMS-ORG 0.010 - 50.000 - OCN1 dependent reset time multiplier of ORGinverse curve 1.000OCN1-k 0.00000 - 500.00000 - OCN1 user original curve coefficient 0.00000OCN1-a 0.00000 - 10.00000 - OCN1 user original curve coefficient 0.00000OCN1-c 0.00000 - 10.00000 - OCN1 user original curve coefficient 0.00000 |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved