6F2T0207 (0.01)GRE200 (5,6)- 458 -Signal Number Signal Name Description M/O511001 800202EE65 DPSY02IN_TMP_40 DPSY02 user additional condition(PLC#1) O511001 810201EE66 DPSY01IN_TMP_41 DPSY01 user configurable operate condition(PLC#2) O511001 810202EE66 DPSY02IN_TMP_41 DPSY02 user configurable operate condition(PLC#2) O511001 820201ED50 DPSY01IN_TMP_28 DPSY01 control hierarchy condition(PLC#3) M511001 820202ED50 DPSY02IN_TMP_28 DPSY02 control hierarchy condition(PLC#3) MTable 4.1-18 PLC monitoring points (Output signal for BIO)Signal Number Signal Name Description511001 8202011DD3 DPSY01_OEX_BO DPSY01 operate (CLOSE) command for Binary Output.511001 8202021DD3 DPSY02_OEX_BO DPSY02 operate (CLOSE) command for Binary Output.511001 8102011DD0 DPSY01_FEX_BO DPSY01 operate (OPEN) command for Binary Output.511001 8102021DD0 DPSY02_FEX_BO DPSY02 operate (OPEN) command for Binary Output.Table 4.1-19 PLC monitoring points (Signals within operate logic)Signal Number Signal Name Description511001 8002011E7F DPSY01_OEC_OK_CSF DPSY01 Close direction execute command511001 8002021E7F DPSY02_OEC_OK_CSF DPSY02 Close direction execute command511001 8102011E82 DPSY01_OEC_OK_CS DPSY01 Close direction execute command511001 8102021E82 DPSY02_OEC_OK_CS DPSY02 Close direction execute command511001 8002011E7E DPSY01_FEC_OK_CSF DPSY01 Open direction execute command511001 8002021E7E DPSY02_FEC_OK_CSF DPSY02 Open direction execute command511001 8002011E7E DPSY01_FEC_OK_CS DPSY01 Open direction execute command511001 8002021E7E DPSY02_FEC_OK_CS DPSY02 Open direction execute commandTable 4.1-20 PLC monitoring points (Output signal for response)Signal Number Signal Name Description511001 8002011E93 DPSY01_EX_CMP DPSY01 completed control511001 8002021E93 DPSY02_EX_CMP DPSY02 completed control511001 8602011E91 DPSY01_EX_FFL DPSY01 failed control511001 8602021E91 DPSY02_EX_FFL DPSY02 failed control(ix) Setting namesNote: The “xx” of “DPSYxx” represents the DPSY function number. (e.g., if the DPSY01is considered, the “xx” is equal to “01”. The suffix “xx” can be represented by eithera “01” or “02”.)Table 4.1-21 Setting of Operate in DPSYxxSetting Name Description Default Setting item or valueDPSYxx-PLSM Method of command output (DPSY01-02) Fix Fix/VarDPSYxx-CPW Duration of command output (DPSY01-02) 1.0[sec] 0.1~50.0[sec]DPSYxx-RST Detection time for terminating control (DPSY01-02) 30.0[sec] 0.1~100.0[sec]DPSYxx-LGCTRCON Logic selector for operate condition (DPSY01 -02) Fixedlogic Fixedlogic/PLCDPSYxx-LGCFEXOT Logic selector for command output (DPSY01 -02) Fixedlogic Fixedlogic/PLCDPSYxx-CTREN Activate control function (DPSY01 -02) Close Open / CloseDPSYxx-LGEXFFCT Logic selector for operate condition (DPSY01 -02) Fixedlogic Fixedlogic / PLC |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved