Toshiba GR-200-5 Instruction Manual
Also see for GR 200 Series: Instruction manualInstruction manualInstruction manualInstruction manualInstruction manual
6F2T0207 (0.01)GRE200 (5,6)- 504 -Table 4.2-4 Mapping points for the reception of control commandsSignal Number Signal Name Description M/O512001 7003016D08 DEV01_CONTROL_REQ DPOS01 control command received. (Mapping Data) M512001 7003026D08 DEV02_CONTROL_REQ DPOS02 control command received. (Mapping Data) M512001 7003036D08 DEV03_CONTROL_REQ DPOS03 control command received. (Mapping Data) M… … …512001 7003486D08 DEV72_CONTROL_REQ DPOS72 control command received. (Mapping Data) MTable 4.2-5 Input signals to condition logicSignal Number Signal Name Description M/O5A0001 0008001F41 DCB RCV OR Double Command Blocking(DCB) is in progress. N/A5A0001 0008001F40 Travelling OR Travelling events are detected. N/A4A1001 8300001B6F GEN.TRIP General trip N/A5A0001 3108003F40 SDCEN (This is setting of CMNCTRL) N/A5A0101 3100001F43 SERI_ERR Serious Error detected N/ATable 4.2-6 PLC Connection points (Input signals for select condition logic)Signal Number Signal Name Description M/O512001 810301EE62 DPOS01IN_TMP_32 DPOS01 additional failure condition(PLC#1) O512001 810302EE62 DPOS02IN_TMP_32 DPOS02 additional failure condition(PLC#1) O512001 810303EE62 DPOS03IN_TMP_32 DPOS03 additional failure condition(PLC#1) O…. …. ….5A0101 801016EF40 DPOS72IN_TMP_32 DPOS72 additional failure condition(PLC#1) O512001 800301EE61 DPOS01IN_TMP_31 DPOS01 user configurable select condition(PLC#2) O512001 800302EE61 DPOS02IN_TMP_31 DPOS02 user configurable select condition(PLC#2) O512001 800303EE61 DPOS03IN_TMP_31 DPOS03 user configurable select condition(PLC#2) O… … …512001 800348EE61 DPOS72IN_TMP_31 DPOS72 user configurable select condition(PLC#2) O512001 820301ED50 DPOS01IN_TMP_28 DPOS01 control hierarchy condition(PLC#3) M512001 820302ED50 DPOS02IN_TMP_28 DPOS02 control hierarchy condition(PLC#3) M512001 820303ED50 DPOS03IN_TMP_28 DPOS03 control hierarchy condition(PLC#3) M…. …. ….512001 820348ED50 DPOS04IN_TMP_28 DPOS20 control hierarchy condition(PLC#3) MTable 4.2-7 PLC Monitoring points (Output signal for select condition logic)Signal Number Signal Name Description512001 8003011F5A DPOS01_SC_ST_ERR DPOS01 select command mode is invalid.512001 8003021F5A DPOS02_SC_ST_ERR DPOS02 select command mode is invalid.512001 8003031F5A DPOS03_SC_ST_ERR DPOS03 select command mode is invalid.…. …. ….512001 8003481F5A DPOS72_SC_ST_ERR DPOS72 select command mode is invalid.512001 8103011F5F DPOS01_F_QLT_SPP Event suppression detected (DPOS01)512001 8103021F5F DPOS02_F_QLT_SPP Event suppression detected (DPOS02)512001 8103031F5F DPOS03_F_QLT_SPP Event suppression detected (DPOS03)…. …. ….512001 8103481F5F DPOS72_F_QLT_SPP Event suppression detected (DPOS72)512001 8203011F60 DPOS01_F_BI_ERR BI connection error detected(DPOS01)512001 8203021F60 DPOS02_F_BI_ERR BI connection error detected(DPOS02)512001 8203031F60 DPOS03_F_BI_ERR BI connection error detected(DPOS03)…. …. ….512001 8203481F60 DPOS72_F_BI_ERR BI connection error detected(DPOS72) |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved