Toshiba GR-200-5 Instruction Manual
Also see for GR 200 Series: Instruction manualInstruction manualInstruction manualInstruction manualInstruction manual
6F2T0207 (0.01)GRE200 (5,6)- 503 -(viii) Signal name and numberNote: The user should note the following descriptions shown in the column “M/O” foreach table:“O” indicated that the signal is provided for optional use.“M” indicates that the user should map/set/configure the signal; otherwise, theuser may experience an operational failure if the default settings areused.“N/A” indicates that the user cannot change the state of the signal.Table 4.2-1 PLC Connection points (Input points for Command ‘On’)Signal Number Signal Name Description M/O512001 800301EE32 DEV01_CL_COMMAND DPOS01 PLC On-control checking with interlock(PLC#1) O512001 800302EE32 DEV02_CL_COMMAND DPOS02 PLC On-control checking with interlock(PLC#1) O512001 800303EE32 DEV03_CL_COMMAND DPOS03 PLC On-control checking with interlock(PLC#1) O…. …. ….512001 800348EE32 DEV72_CL_COMMAND DPOS72 PLC On-control checking with interlock(PLC#1) O512001 800301EE33 DEV01_CL_INTERLOCK DPOS01 PLC On-control without checking(PLC#2) O512001 800302EE33 DEV02_CL_INTERLOCK DPOS02 PLC On-control without checking(PLC#2) O512001 800303EE33 DEV03_CL_INTERLOCK DPOS03 PLC On-control without checking(PLC#2) O…. …. ….512001 800348EE33 DEV72_CL_INTERLOCK DPOS72 PLC On-control without checking(PLC#2) OTable 4.2-2 PLC Connection points (Input points for Command ‘Off’)Signal Number Signal Name Description M/O512001 800301EE30 DEV01_OP_COMMAND DPOS01 PLC Off-control checking with interlock(PLC#1) O512001 800302EE30 DEV02_OP_COMMAND DPOS02 PLC Off-control checking with interlock(PLC#1) O512001 800303EE30 DEV03_OP_COMMAND DPOS03 PLC Off-control checking with interlock(PLC#1) O…. …. ….512001 800348EE30 DEV72_OP_COMMAND DPOS72 PLC Off-control checking with interlock(PLC#1) O512001 800301EE31 DEV01_OP_INTERLOCK DPOS01 PLC Off-control without checking(PLC#2) O512001 800302EE31 DEV02_OP_INTERLOCK DPOS02 PLC Off-control without checking(PLC#2) O512001 800303EE31 DEV03_OP_INTERLOCK DPOS03 PLC Off-control without checking(PLC#2) O…. …. ….512001 800348EE31 DEV72_OP_INTERLOCK DPOS72 PLC Off-control without checking(PLC#2) OTable 4.2-3 PLC Connection points (Interlock for Command ‘On/Off’)Signal Number Signal Name Description M/O570001 3103021DA2 DPOS01-Close DPOS01 interlock condition for On control. N/A570001 3103031DA2 DPOS02-Close DPOS02 interlock condition for On control. N/A570001 3103041DA2 DPOS03-Close DPOS03 interlock condition for On control. N/A… … …570001 3103481DA2 DPOS72-Close DPOS72 interlock condition for On control. N/A570001 3103011DA0 DPOS01-Open DPOS01 interlock condition for Off control. N/A570001 3103021DA0 DPOS02-Open DPOS02 interlock condition for Off control. N/A570001 3103031DA0 DPOS03-Open DPOS03 interlock condition for Off control. N/A…. …. ….570001 3103481DA0 DPOS72-Open DPOS72 interlock condition for Off control. N/A |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved