Toshiba GR-200-5 Instruction Manual
Also see for GR 200 Series: Instruction manualInstruction manualInstruction manualInstruction manualInstruction manual
6F2T0207 (0.01)GRE200 (5,6)- 450 -DPSY01 function (Function ID: 511001)Operate Cmd.with ILK† conditionSR0.1 – 50.0 s[DPSY01-CPW]Operation Cmd.without ILK† condition[DPSY01-LGCTRCON]FixedlogicCommand “Local-Open-Control”ILK condition (“Open”) passedDPSY01--OpenDPSY01IN_TMP_34511001 800201EE56User configurable condition (PLC#3 connection point)“DPSY01_FEC_OK_CSF”(511001 8002011E7E)& & 1≥&1≥ 1≥ &&Input OutputOperate logic in DPSY01PLC#31≥ILK bypassingICB_STATETo BO connection“DPSY01_FEC_OK_CS”(511001 8002011E7E)[DPOS01-PLSM]VarFixOperation Failed[DPSY01-RST]“DPSY01_FEC_OK_CSF”(512001 8003011E7E)“DPSY01_EX_FFL”(511001 8602011E91)To “Wait for a command”&Detection of state-change in a device& PLC#2DPSY01IN_TMP_44511001 820201EE5EUser configurable condition(PLC#2 connection point) 1≥&“DPSY01_EX_CMP”(511001 8002011E93)Operation CompletedOperate condition‡Fixedlogic[DPSY01-LGCFEXOT]Assign to BOs&“DPSY01_FEX_BO” ††(511001 8102011DD0)To BO connection1.0s- 100.0s0 tFigure 4.1-26 Operate Open logic at local in DPSY01†Note:The ILK function can provide the operation criteria for “Open”.‡Note:An “operate condition” signal is generated in the operate-condition logic (seeFigure 4.1-31) when Fixlogic is set for scheme switch [DPSY01-LGCTRCON]. If analternative “operate-condition” is required it can be programmed by the user andused to replace the signal generated by the original operated-condition logic. Thealternative “operate-condition” can be connected to the above logic usingconnection point #3 “User-configurable condition”. That is, set the scheme switch[DPSY01-LGCTRCON] to PLC and use “DPSY01IN_TMP_34”.§§Note: The signal “DPSY01_OEX_BO” is issued when Fixlogic is set for the schemeswitch [DPSY01-LGCFEXOT]. The “Operate completed” signal can also be issuedfrom the logic programmed by the user in place of the logic shown in Figure4.1-20. The user-programmed logic is connected internally to the signal “Operatecompleted”, hence this signal is now generated by the user-programmed logic atconnection point #2 “User configurable condition”. That is, set the scheme switch[DPSY01-LGCFEXOT] to PLC and use “DPSY01IN_TMP_44”.*Note:The user can set the type of output signal. When Var is set for scheme switch[DPSY01-PLSM], the output period of the signal is defined by the setting[DPSY01-CPW]. When Fix is set, the signal ceases when the 43-switch is changed.††Note: To identify the input and output signals of the DPSY02 logic, see Table 4.1-15 forPLC#2, Table 4.1-16 for PLC#3, Table 4.1-18, and Table 4.1-20 for the outputs. |
Related manuals for Toshiba GR 200 Series
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved