6F2T0207 (0.01)GRE200 (5,6)- 762 -8.4.2 Transferred information about tripped phase and modeInformation about the tripped phases and mode can be transferred with the signals in Table8.4-2. For more information about tripped phases and modes, see sections 8.1.1(ii) and (iii).Table 8.4-2 Transferred informationItems Signal namesNumber of faults recorded FLT_CNTTime at the fault occurrence FLT_TMFault phase A FLT_PH_AFault phase A FLT_PH_BFault phase A FLT_PH_CFault phase N FLT_PH_NRelay element operated at phase A FLT_OP_ARelay element operated at phase B FLT_OP_BRelay element operated at phase C FLT_OP_C8.4.3 Transferred state informationInformation collected by setting [OP Mode ID*] can transferred with the signals in Table 8.4-3.For more information about the statuses, see sections 8.1.3(i) and (ii).Table 8.4-3 Transferred information by OP mode settingsItems Signal namesState taken by setting [OP Mode ID1] FLTOPM001State taken by setting [OP Mode ID2] FLTOPM002State taken by setting [OP Mode ID3] FLTOPM003…. ….State taken by setting [OP Mode ID128] FLTOPM128Logical state taken by setting [OP Mode ID201] FLTOPM201Logical state taken by setting [OP Mode ID202] FLTOPM202…. ….Logical state taken by setting [OP Mode ID264] FLTOPM264