Chapter 1515-6E717 There is an error in the communication with the NE controller.0001 The NE controller is not connected at power on,although it was connected before the power wasturned off because of an error.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.0002 An IPC error has occurred while the NEcontroller is in operation.There is an open circuit for the IPC. An error hasoccurred, and the IPC communication remainsdisabled.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.E719 There is a coin vendor error.0001 The coin vendor is not connected when the poweris turned on, although it was connected before thepower was turned off because of an error.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.0002 While the coin vendor is in operation, an IPCerror has occurred, IPC has developed an opencircuit, or an error preventing recovery of IPCcommunication has occurred.An open circuit has been detected in the line forthe pickup/delivery signal.An illegal signal has been detected.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.0003 While the unit price is being checked at startup,an error occurs in the communication with thecoin vendor.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.0011 An error has occurred at new card reader startup.The new card reader is not connected when thepower is turned off, although it was connectedwhen the power was turned off.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.0012 An IPC error has occurred at new card readerstartup.There is an IPC open circuit. An error hasoccurred that prevents recovery of IPCcommunication.Check the cable; thereafter, reset the condition inservice mode:COPIER>FUNCTION>CLEAR>ERR.E730 There is a PDL software error.1001 An initialization error has occurred. 1. Execute PDL resetting.2. Turn on the power once again.100A An error that may be critical to the system (e.g.,failed initialization) has occurred.1. Execute PDL resetting.2. Turn on the power once again.9004 There is an error in the communication (PAI)with an external controller.1. Turn on the power once main.2. Check the connection of the open I/F board andthe cable.3. Replace the board for the external controller openI/F.4. Replace the main board.9005 There is a fault in the connector of the vide cableto the external controller.1. Turn on the power once main.2. Check the connection of the open I/F board andthe cable.3. Replace the board for the external controller openI/F.4. Replace the main board.A006 The PDL board does not respond. A subbootableis faulty or absent.1. Execute PDL resetting.2. Turn on the power once again.3. Check the connection of the SURF board.4. Re-install the firmware.5. Replace the main board.A007 There is a mismatch between the control softwareof the machine and the PDL control software inregard to version.1. Execute PDL resetting.2. Turn on the power once again.3. Execute system formatting (all), and reinstall thesystem.B013 There is corruption in the font data. 1. Turn on the power once again.2. Re-install the software.3. Execute system formatting (all), and reinstall thesystem.E732 There is an error in the communication with the scanner.0001 There is a DDI-S communication error. 1. Check the connector used to connect the scanner.2. Check the power supply of the scanner (to see ifinitialization takes place at startup).3. Replace the reader controller, scanner board, ormain board as necessary.E733 There is an error in the communication with the printer.0000 At startup, communication with the printer fails. 1. Check the connector used to connect to the printer.2. Check the power supply of the printer (to see ifinitialization takes place at startup).3. Replace the DC controller or the main board.0001 There is a DDI-P communication error. 1. Check the connection with the printer.2. Check the power supply of the printer (to see ifinitialization takes place at startup).3. Replace the DC controller or the main board.Code Cause Remedy