Chapter 1515-215.2 Error Code Details15.2.1 Error Code Details 0008-1078iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / /T-15-2E716 communication error for pedestal/ communication error for 3-way unit-A1E717 communication error for NE controllerE719 coin vendor errorE730 PDL software errorE732 scanner communication errorE733 printer communication errorE740 Ether board errorE743 DDI communication errorE744 language file/boot ROM errorE745 TokenRing board errorE746 accessories board wrong model errorE748 controller board and SDRAM size mismatchE805 fan errorCode Cause RemedyE000 The temperature of the fixing assembly is abnormally high.0001 While startup control is under way, the reading ofthe main thermistor is less than 30 deg Ccontinuously for 200 msec or more 1 sec after thestart of power supply.While startup control is under way, the reading ofthe main thermistor is less than 70 deg Ccontinuously for 200 msec or more 2 sec after thestart of power supply.While startup control is under way, the reading ofthe main thermistor is less than 120 deg Ccontinuously for 200 msec 6 sec after the start ofpower supply.The startup control does not end 30 sec after thestart of power supply.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace themain thermistor. Replace the DC controller PCB.E001 The temperature of the fixing assembly is abnormally high.0000 The reading of the main thermistor is 250 deg Cor more continuously for 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace themain thermistor. Replace the DC controller PCB.0001 The hardware circuit detects overheating of themain or sub thermistor for 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace theDC controller PCB.0002 The reading of the sub thermistor is 295 deg C ormore continuously for 200 msec.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace thesub thermistor. Replace the DC controller PCB.E002 The rise in temperature of the fixing assembly is faulty.0000 While startup control is under way, the reading ofthe main thermistor is less than 115 deg Ccontinuously for 400 msec 1.3 sec after it hasindicated 100 deg C.While startup control is under way, the reading ofthe main thermistor is less than 150 deg Ccontinuously for 400 msec 1.3 sec after it hasindicated 140 deg C.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace themain thermistor. Replace the DC controller PCB.E003 The fixing temperature is too low after a standby state.0000 While regular temperature control is under way,the reading of the main thermistor is less than 140deg C continuously for 400 msec or more.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace themain thermistor. Replace the DC controller PCB.E007 The rotation of the fixing film is faulty.0000 While the fixing motor is rotating, the markersignal is not detected for 6 sec with the reading ofthe main thermistor indicating 100 deg C or more.Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR. Replace themain thermistor. Replace the DC controller PCB.E010 The rotation of the main motor is faulty.0001 Detection is executed every 100 msec after thestart of motor rotation; however, the drivedetection signal is absent for 2 sec.Replace the main motor. Replace the DC controllerPCB.0002 During motor rotation, detection is executedevery 100 msec; however, the drive signal isabsent 5 times in sequence.Replace the main motor. Replace the DC controllerPCB.E014 The rotation of the fixing motor is faulty.0001 Detection is executed every 100 msec after thestart of motor rotation; however, the drivedetection signal is absent for 2 sec.Replace the fixing motor. Replace the DC controllerPCB.Code Error name/description