Chapter 1515-50003 [Cause] An HD write abort error has occurred.The sectors for BOOTDEV on the HD cannot beread.[Detection] BARSAC (all; at time of bootablestartup)[Timing of Detection] once at startupSee the details under 602.0006 [Cause] A subbootable that matches the PDL typedoes not exit in BOOTDEV/BOOT.[Detection] during loading of sub boot inoclibroot[Timing of Detection] once at bootable startupSee the details under 602.0007 [Cause] An ICC profile that matches the PDLtype does not exist in BOOTDEV/PDL.[Detection] beginning of oclibroot; judgmentbased on functions of PDL team that are called in[Timing of Detection] once at bootable startupSee the details under 602.01XX /DOSDEV is faulty. See the details under 602.02XX /FSTDEV is faulty. See the details under 602.03XX /DOSDEV2 is faulty. See the details under 602.04XX /FSTPDEV is faulty. See the details under 602.05XX /DOSDEV3 is faulty. See the details under 602.06XX /PDLDEV is faulty. See the details under 602.07XX /DOSDEV4 is faulty. See the details under 602.08XX /BOOTDEV is faulty. See the details under 602.09XX /DOSDEV5 is faulty. See the details under 602.FFXX There is an error in a partition that cannot beidentified.See the details under 602.E604 The image memory is faulty or is inadequate.0000 The memory size does not match the model. Increase the memory.E609 There is an error on the HDD.0008 At startup, the HDD fails to reach a specifictemperature level within a specific period of time.Replace the hard disk. Replace the DC controllerPCB.0009 At time of sleep recovery, the temperature fails toreach a specific level.Replace the hard disk. Replace the DC controllerPCB.E610 The HDD coding key is faulty.The SRM/PCB is faulty. The battery has becomeexhausted, leading to loss of SRAM contents.Try step 1); if it fails, try step 2).1) Turn off and then back on the power switch togenerate the key once again.2) If the same error still continues, replace the boardon which the SRAM is mounted. (Keep in mind thatdoing so will lead to loss of all user data.)E674 An error has occurred in communication between the fax control PCB (2-line) and main controller PCB.0001 An attempt to set mode for the fax device hasfailed.1. Check the connection of the cable between the faxcontrol PCB (2-line) and the main controller PCB.2. Replace the ROM DIMM of the fax control PCB(2-line).3. Replace the fax control PCB (2-line).4. Replace the main controller PCB.E710 There is an error in the initialization of the IPC.0001 The machine fails to become ready 3 sec or lessafter the IPC chip startup.Check the cable.0002 When the main power is turned on, thecommunication IC (IPC) on the DC controllerPCB cannot be initialized.Check the cable.E711 There is an error in the IPC communication.0001 The occurrence of an error has been recorded inthe error register of the IPC chip 4 times or morewithin 1.5 sec.Check the cable.0002 The occurrence of an error has been recorded inthe error register of the IPC chip 4 times or morewithin 2 sec.Check the cable.E713 There is an error in the communication with the finisher or 3 Way Unit-A1.0000 The communication with the finisher does notresume within 5 sec after it has been disrupted.Check the cable. Replace the DC controller PCB.Replace the finisher controller PCB.E716 There is an error in the communication with the pedestal.0000 After the presence of a pedestal has beendetected, the communication fails to be normalfor 5 sec.Check the cable. Replace the DC controller PCB.Replace the pedestal drive PCB.0010 When the communication with the 3 Way Unit-A1 is faulty after detecting the connection withthe finisher.Install the 3 Way Unit-A1. Replace the DCcontroller PCB after checking the cable.Code Cause Remedy