Chapter 99-18F-9-862) Remove the 2 screws [1].F-9-873) Slide the left side plate [1] in the direction of the arrow to detach.F-9-88F-9-89When mounting the left side plate, be sure that it is correctly positioned sothat the locking lever and the teeth are correctly engaged. (See the figure.)F-9-909.5.4.6 Releasing the Locking Plate 0007-7902iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N // iR4570N / iR2230 / / / iR3530 /1) Turn the locking gear [1] in the direction of the arrow to release thelocking roller.F-9-912) Remove the 2 screws [1].F-9-92Do not touch the screw [1] used to keep the fixing assembly in place. Turningthe screw will change the pressure of the fixing assembly, which cannot beadjusted in the field, necessitating the replacement of the fixing assembly.