Chapter 1010-36F-10-16510.5.12.6 Removing the Upper Tray 0007-8403iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N // iR4570N / iR2230 / / / iR3530 /1) Remove the 2 screws [1], and detach the upper tray [2].F-10-166Reference:Lift the front of the upper tray [1], and detach it as if to slide it toward thefront.F-10-16710.5.12.7 Removing the Toner Cartridge Cover 0007-8404iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N // iR4570N / iR2230 / / / iR3530 /1) Remove the 2 screws [1]; then, detach the toner bottle cover [2].F-10-16810.5.12.8 Removing the Pre-Exposure Lamp 0007-8405iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N // iR4570N / iR2230 / / / iR3530 /1) Open the 2 wire saddles [1], and disconnect the 2 relay connectors [2].F-10-1692) While freeing the lock [1] toward the right, detach the pre-exposure lamp[2].F-10-170F-10-17110.5.12.9 Removing the Left Cover 0007-8407iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N // iR4570N / iR2230 / / / iR3530 /1) Remove the 4 screws [1], and detach the left cover [2].