2-3) If the user does not want control by group, set the DIP switch (SW5-4) to OFF.If you are connecting a Copy Data Interface Board-B1, Remote Diagnostic Unit-A1,or Copy Data Interface Board-A1, see A. “Setting the Board” in the appropriateInstallation Procedure.Figure 9-5023) Set the jumper connectors (JA1, JA2, JB1, JB2) on the Copy Data Controller-A1according to the specifications of the user.Figure 9-503a. If you are connecting a Remote Diagnostic Unit-A1 or a Copy Data InterfaceBoard-B1, i.e., if a Power Supply-A1 is necessary,Figure 9-504JB1JB216 SW4SW1 ON SW5 ONLED6LED5LED4LED3LED2LED1SW2SW3JB2JB1JA1JA2EPROMSRAMCPU IPCJC9JC6JC5JC8J5JB1JB2JA2JA11616 SW4SW1 ON SW5 ONLED6LED5LED4LED3LED2LED1SW2SW3JB2JB1JA1JA2EPROMSRAMCPU IPCJC9JC6JC5JC8J516SW116 16SW5CHAPTER 9 INSTALLATION9-42 COPYRIGHT © 1997 CANON INC. CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)