14. Removing the Upper SeparationClaw1) Slide out the fixing/feeding unit fromthe copier.2) Open the fixing/delivery assembly,and release the spring q; then,remove the upper separation claww.15. Adjusting the Nip (tightening thepressure adjusting nut)The nip width is correct if it is asindicated in Table 6-201. Otherwise,turn the pressure adjusting nut.a and c represent points 10 mmfrom both ends of copy paper.*Be sure both upper and lower rollersare sufficiently warm before takingmeasurements.Table 6-201CHAPTER 6 FIXING SYSTEM6-30 COPYRIGHT © 1997 CANON INC. CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)Figure 6-227q wDimensionsb| a – c |Measurements*8.5 ± 0.5 mm0.5 mm or lessFigure 6-228FeedingdirectioncaA3 sizeCenter ofcopy paperbCaution: