5) Remove the E-ring r, and removethe pressure spring t.6) Loosen the five mounting screws y,and remove the cleaning blade fromthe blade support plate.3. Installing the Cleaning BladeInstall the cleaning blade by revers-ing the steps used to remove it with thefollowing in mind:1) Butt the cleaning blade q againstthe rear.CHAPTER 4 IMAGE FORMATION SYSTEM4-63COPYRIGHT © 1997 CANON INC. CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)Figure 4-350rtFigure 4-351yFigure 4-352qNo gap.Blade retaining plate