Chapter 1616-216.2 Error Code Details16.2.1 Error Code Details 0011-6725iR7105 / iR7095 / iR7086T-16-2E609 The HDD temperature is abnormally low.E610 The HDD encryption key is faulty.E677 Error in external controllerE711 An error has occurred in the communication between the pickup/delivery accessory and the printer unit.E712 An error exists in the communication between the ADF and the reader unit.E717 An error exists in the communication with the NE controller.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)E719 An error has occurred in the communication with the coin vendor/card reader.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)E730 A PDL-related error has occurred.E732 An error has occurred in the communication between the reader unit and the maincontroller.E733 An error has occurred in the communication between the reader unit and the maincontroller.E740 An error exists in the LAN controller.E743 A fault exists in the communication between the main controller and the reader controller.E744 An error exists in the language file/boot ROM.E746 An unsupported optional board has been detected.E748 Main controller PCB errorE749 Restart in accordance with a change of the product configurationE800 The auto power-off circuit has an error.E804 The rotation of the following is faulty: power supply cooling fan 1, power supply cooling fan2, controller cooling fan.E805 The fixing heat discharge fan rotation is faulty.E820 The drum fan rotation is faulty.E823 The pre-transfer charging assembly fan rotation is faulty.E840 An HP detection error has occurred in relation to the fixing inlet sensor (fixing wrap jamdetection).E850 There is a fault in the double-feeding detection unit.Code Description Remedial action*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).**: model equipped with DADF-M1 (outside Japan: iR7086).E000 The fixing unit has overheated.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The reading of the main thermistor is less than 70 deg C 3.5 min after power-on.Check the mounting/soiling of the main thermistor. Replacethe fixing heater. Replace themain thermistor. Replace the AC driver PCB. Replace the DCcontroller PCB.0010 The power has been turned off and then on without resetting the error. Reset the error. (COPIER>FUNCTION>CLEAR>ERR)E001 The fixing unit has overheated.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0001 The reading of the main thermistor or the sub thermistor is 230 deg C or morefor 2 sec.(hardware detection)Replace the AC driver PCB. Replace the DC controller PCB.0002 The reading of the main thermistor or the sub thermistor is 230 deg C or morefor 2 sec ormore. (software detection)Check the mounting/soiling of the main thermistor. Replacethe main thermistor. Replacethe sub thermistor. Replace the AC driver PCB. Replace theDC controller PCB.0003 The difference in the readings of the main thermistor and the sub thermistor is50 deg C for1 sec. (main thermistor reading>sub thermistor reading)Check the mounting/soiling of the main thermistor. Replacethe main thermistor. Replacethe AC driver PCB. Replace the DC controller PCB.0004 The difference in the readings of the main thermistor and the sub thermistor is50 deg C for1 sec or more. (main thermistor reading>/=sub thermistor reading)0010 The power has been turned off and then on without resetting the error. Reset the error. (COPIER>FUNCTION>CLEAR>ERR)E002 The fixing unit has overheated.After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)Code Description*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).**: model equipped with DADF-M1 (outside Japan: iR7086).