Chapter 1212-6- Press [Additional Functions (*)] key.- Press 2 and 8 of the numeric keys at the same time.- Press [Additional Functions (*)] key. => SERVICE MODE LEVEL1A-2. Initialize e-RDS- Select (touch) [COPIER] > [Function] > [CLEAR] > [ERDS-DAT] on the Touch Panel Display.A-3. Display Menu screen of e-RDS- Select (touch) [COPIER] > [Function] > [INSTALL] => Menu screenF-12-4B. Set 1 in [E-RDS].C. Input the URL of UGW in [RGW-ADR]. (Select the input area to shift to the keyboard screen, and Input URL.)D. Input the port number of UGW in [RGW-PORT].E. Select [COM-TEST] and push [OK] button to start the communication test with UGW.F. While the result is "NG!", repeat to correct the setting and try [COM-TEST] until the result becomes "OK!". You need checking the setting of the network of thedevice and the connection of the network if necessary.Notes: In the environment with the proxy server, you should set the proxy server. Refer to the proxy setting in the network guide of the device for details.12.1.12 Trouble shoot 0011-6842iR7105 / iR7095 / iR7086 / iR7095P1-1Q. There is no setting item.A. Confirm the network setting.Confirm the model1-2Q. The communication test fails.A. Confirm the firmware version.Confirm the network setting.Confirm the communication test result.12.1.13 Error message 0011-6843iR7105 / iR7095 / iR7086 / iR7095PError information displayed in "Log list screen" or "Log detailed screen" is as follows.Notes: Only the first part of error information is displayed in "Log list screen". Maximum length of error information in "Log detailed screen": 128 characters (notinclude NULL)When the communication test is not completed end e-RDS is 1 (ON), following string is displayed:"SUSPEND: Communication test is not performed."