Chapter 77-35F-7-637.10.6 Drum Cleaner Unit7.10.6.1 Construction 0010-8829iR7105 / iR7095 / iR7086F-7-647.10.6.2 Removing the Cleaning Blade 0010-8830iR7105 / iR7095 / iR70861) Slide out the process unit.2) Remove the screw [1], and detach the reciprocating arm [2].F-7-653) Disconnect the 2 connectors [1], and remove the 5 screws [2]; then, lift therear and push it in to detach the cleaning blade together with the mountingplate [3].F-7-664) Remove the E-ring [1], and detach the pressure plate [2] to detach thecleaning blade assembly [3].F-7-67The pressure plate looks like the one used for the GP600 Sires or iR8500 Se-ries machines; however, it is a different part with a different parts number.Do not use the wrong part.5) Remove the blade vibration unit from the cleaner blade unit.6) Remove the 5 screws [1], and detach the blade retaining plate [2] to detachthe cleaning blade [3].F-7-687.10.6.3 Mounting the Cleaning Blade 0010-8832iR7105 / iR7095 / iR7086See "Maintenance and Inspection".7.10.6.4 Removing the Blade Vibrating Unit 0010-8833iR7105 / iR7095 / iR70861) Remove the blade unit.2) Disconnect the connector [1], and remove the 2 screws [2]; then, detachthe blade vibrating unit [3].(The rear and front blade vibrating units may be disassembled in the sameway.)[1] [2][3]Cleaning bladeBlade vibration unitSeparation claw[1][2][1][1][3][2][1] [2] [3][2][3][1]