Chapter 1818-255) Execute ALL format with using SST. At this time, connect with iR7105_V2.6) After turning ON/OFF the power switch, start with 2+8 and install the complete System firmware for upgraded device with using SST or USB memory.7) After normal start, start with pressing 1 + 7 and upgrade the ACC firmware of ARCNET connection to the upgrade device compliant from the download modein service mode.18.4.4 Uploading and Downloading Backup Data18.4.4.1 Outline 0011-6773iR7105 / iR7095 / iR7086The file SramImg is data stored in the SRAM of the Main controller PCB.The file MeapBack is a MEAP application and its data stored on the HDD.The file SramDCON is data stored in the SRAM of the DC controller PCB.The file SramRCON is data stored in the EEPROM of the reader controller PCB.Points to Note When Uploading/Downloading MeapBackIf you need to re-install the system software to correct a fault, you may upload MeapBack and then download it back after formatting the HDD (by temporarilyputting aside the MEAP application).1) Upload MeapBack.2) Execute HDD all format.3) Re-install the system software.At this time, be sure that the system software is the same as that existed before formatting the HDD. Otherwise, you will not be able to download MeapBack youhave uploaded.4) Download MeapBack.You will not be able to download MeapBack you have uploaded unless you are downloading it to the machine you have uploaded it from.MEMO:- If you are planning to replace the Main controller PCB, you can upload the SramImg file in advance, and download it after replacement so that the service modeand other settings may be inherited.- If you are planning to replace the DC controller PCB, you can upload the SramDCON file in advance, and download it after replacement so that the service modeand other settings may be inherited.- If you are planning to replace the DC controller PCB, you can upload the SramDCON file in advance, and download it after replacement so that the service modeand other settings may be inherited.18.4.4.2 Uploading Procedure 0011-6774iR7105 / iR7095 / iR7086- When uploading the data, do not select 'Sublog.txt'.- The machine must be in normal mode for uploading/downloading SramDCON or SramRCON.- The machine must be in safe mode when uploading/downloading SramImg or MeapBack.[In the Case of MeapBack]1) Start up the SST.2) Select the model [1] and the type of system software [2] ('Single'); then, check the network settings, and click [START].MEMO:Formatting with using USB memory is not available. It is available with SST only.Backup data File to select for downloadingMain controller PCB backup SramImg.bin (may be uploaded/downloaded in safe mode)MEAP application MeapBack.bin (may be uploaded/downloaded in safe mode)For R&D Sublog.txt (do not select this file)Reader controller PCB backup SramRCON (may be uploaded/downloaded in normal mode)DC controller PCB backup SramDCON (may be uploaded/downloaded in normal mode)