Chapter 1818-118) When done, click [OK].F-18-1218.2.3 Making Connections (SST in use) 0011-6753iR7105 / iR7095 / iR7086[Requirements]- PC to which the SST (version 3.21 or later) has been installed and the system software has been copied- twisted-pair cross cable10Base-T: Category 3 or 5100Base-TX: Category 5[Procedure]1) Start up the PC.2) Check the network settings of the PC.2-1) Start the command prompt, and type in "IPCONFIG," and press the Return key.2-2) Check to be sure that the network settings appearing on the screen are as follows; if not, change the PC network settings:IP address: 172.16.1.160Subnet mask: 255.255.255.0Default gateway: anyDo not use the following IP addresses:- 172.16.1.0- 172.16.1.100- 172.16.1.2553) Check to make sure that the Execute/Memory lamp on the control panel is off; then, turn off the main power switch.3-1) Hold down the power switch on the control panel for 3 sec or more.3-2) Go through the shut-down instructions appearing on the control panel screen so that the main power switch may be turned off.3-3) Turn off the main power switch.4) Connect the PC to the machine with a cross cable.F-18-135) Set the machine to the appropriate mode:- Normal ModeTurn on the main power switch while holding down the keys 1 and 7.When the machine has started, make the following selections in service mode:MFPUSBTarget Selection CONTROL Export Firm SelectioniR7105MFPUSBBOOTBROWSERDCONMEAPCONTSDICTSYSTEMLANGUAGERUIiR7105d:USen0112(US)Y XXxxv0103Y XXxxv0100Y XXxxv0102Y XXxxv0105N XXxxv0107N JPenv0112Y XXenv0112N XXjav0112Y XXenv0107N XXjav0107Valid driveDriveType:1FileSystem:FATTotalSize:1,001MBFreeSpace:1,001MBCANCELEXITO KRegister Fir mwareExpor t Fir mwareDelete Fir mwareDelete Backup DataSystem ManagementS e l e c t t h e t a r g e t . C l i ck a bu t t o n t o exe c u t e . F i l e c o py h a s b e e n c o m p l e t e d .SeriesVersionFirmware registration statusService Support Tool DLM0 (Ver.3.21E)IP address: 172.16.1.100Subnet mask: 255.255.255.0IP sddress: 172.16.1.160Subnet mask: 255.255.255.0Cross cable10Base-T: category 3, 5 or later100Base-TX: category 5 or later