Chapter 55-273) Slide the No. 1 mirror base [1] to the right so that it matches against thecut-off [2] of the frame.When detaching the No. 1 mirror base, be sure to hold it by the bend [A] onthe mirror stay.F-5-784) Remove the 2 screws [1], and detach the scanning lamp [2].F-5-795.4.4.4 When Replacing Components of the ScanningSystem 0011-8733iR7105 / iR7095CCD unit, copyboard glass, scanning lamp, standard white plate, inverterPCBExecute the following service mode item:1) COPIER> FUNCTION> CCD> CCD-ADJ (shading correction based onthe standard white plate)5.4.4.5 When Replacing Components of the ScanningSystem 0011-8738iR7086CCD unit, copyboard glass, stream reading glass, scanning lamp, inverterPCBExecute the following service mode items:1) COPIER> FUNCTION> CCD> CCD-ADJ (shading correction based onthe standard white plate)2) COPIER> FUNCTION> CCD> DF-WLVL1 (ADF white level; for copy-board mode)3) COPIER> FUNCTION> CCD> DF-WLVL2 (ADF white level; forstream reading mode)5.4.5 Reader Controller PCB5.4.5.1 Before Starting the Work 0011-8109iR7105 / iR7095 / iR70861) Remove the copyboard glass.2) Remove the CCD unit cover [1].- 9 screws [2]F-5-803) Remove the original size sensor unit.5.4.5.2 Removing the Reader Controller PCB 0011-7972iR7105 / iR7095 / iR70861) Disconnect the 5 flat cables [1] and the connector [2], and remove the 4screws [3]; then, detach the reader controller PCB [4].F-5-81How to Disconnect the Flat CableSlide the locking lever [1] in the direction of the arrow to release; then, de-tach the flat cable [2].F-5-82[1][2][2][A][1][1][2][2][2][2][2][1][1][2][1][1][2]