Chapter 1414-15F-14-283) Fit the pins of the mirror positioning tool (front [2]; rear [3]) into the ap-propriate holes of the No. 1/No. 2 mirror base).F-14-29F-14-304) Secure the end of the cable that has temporarily been fixed in place on thehook of the reader unit frame.5) Fully tighten the screws on the cable fixing plate both at the front and therear.6) Detach the mirror positioning tool (FRONT, REAR).7) Put the detached parts back on by reversing the foregoing steps.14.4 Laser Exposure System14.4.1 When Replacing the Laser Scanner Unit 0010-9320iR7105 / iR7095 / iR7086There is no special work in conjunction with the replacement of the laserscanner unit.14.5 Image Formation System14.5.1 Adjusting the Height of the Charging Wire 0010-9325iR7105 / iR7095 / iR7086T-14-2[A][B][C][B][A][1]Height of charging wirePrimaryPre-transferSeparation[3][2]7.5 - 0mm+3mm 7.5 - 0mm+3mm13.6 ±0.3mmNo height adjustingmechanism17.0 0.2mm 15.5 0.2mm