Chapter 1616-30000 The reading of the main thermistor has exceeded 70 deg C, but does not reach100 deg Cwithin 2.5 sec thereafter.Disconnect and then connect J508 of the DC controller PCB.Disconnect and then connectthe connectors of the fixing unit. Check the wiring betweenthe main/sub thermistor andthe DC controller. Check the mounting/soiling of the mainthermistor. Replace the fixingheater. Replace the AC driver PCB. Replace the DCcontroller PCB.0001 The reading of the main thermistor has exceeded 100 deg C, but does not reach150 deg Cwithin 2.5 min thereafter.0010 The power has been turned on without resetting the error. Reset the error. (COPIER>FUNCTION>CLEAR>ERR)E003 The fixing unit temperature is abnormally low.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The reading of the main thermistor has exceeded 100 deg C, but is 70 deg Cor less for 2 secthereafter.Disconnect and then connect J508 of the DC controller PCB.Disconnect and then connectthe connectors of the fixing unit. Check the wiring betweenthe main/sub thermistor andthe DC controller PCB. Check the mounting/soiling of themain thermistor. Replace thefixing heater. Replace the AC driver PCB. Replace the DCcontroller PCB.E004 The fixing unit has a fault. (protective circuit ON)After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 While the sub heater is on, the SSR for the heater drive has a short-circuit for5 sec ormore.Replace the AC driver PCB. Replace the DC controller PCB.0001 While the main heater is on, the SSR for the heater drive has a short-circuit for5 sec ormore.E005 The fixing web has run out.After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The absence of the fixing web has been detected for 5 sec or more. Check the position of the fixing web detecting lever. Replacethe fixing web. Replace thefixing web length sensor. Replace the DC controller PCB.If you have replaced the fixing web, be sure to reset thecounter:- COPIER>COUNTER>MISC>FIX-WEB- COPIER>COUNTER>DRBL-1>FX-WEB0010 The power has been turned off and then on without resetting the error. Reset the error. (COPIER>FUNCTION>CLEAR>ERR)E010 The main motor rotation is faulty.0000 After the main motor has gone on, the FG signal of the motor is not detectedfor 2 sec ormore.Disconnect and then connect J611 and J612 of the mainmotor. Disconnect and then connectJ514 of the DC controller PCB. Disconnect and then connectJ1720 of the relay PCB.Replace the main motor. Replace the relay PCB. Replace theDC controller PCB.E012 The drum motor rotation is faulty.0000 After the drum motor has gone on, the PLL lock signal of the motor is notdetected for 2 secor more.Disconnect and then connect J1721 of the relay PCB.Disconnect and then connect J512 ofthe DC controller PCB. Disconnect and then connect J601and J602 of the drum motor.Replace the drum motor. Replace the DC controller PCB.E013 The waste toner feedscrew is stuck. (clogged with waste toner)After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The waste toner feedscrew is stuck for 4 sec or more. Detach and then attach the waste toner pipe. Replace thewaste toner pipe. Replace thewaste toner feedscrew detecting switch. Replace the DCcontroller PCB.0010 The power has been turned off and then on without resetting the error. Reset the error.(COPIER>FUNCTION>CLEAR>ERR)E014 The fixing motor rotation is faulty.0000 After the fixing motor has gone on, the PLL signal of the motor is not detectedfor 2 sec ormore.Disconnect and then connect J651 and J652 of the fixingmotor. Replace the fixing motor.Replace the relay PCB. Replace the DC controller PCB.E015 The pickup motor rotation is faulty.0000 The pickup motor has gone on, but the FG signal of the motor is not detectedfor 2 sec ormore.Disconnect and then connect J621 and J622 of the pickupmotor. Replace the pickup motor.Replace the relay PCB. Replace the DC controller PCB.E019 The waste toner case is full.0000 After the waste toner case has become full, 50,000 prints (A4) or more havebeen madewithout disposing of the waste toner.Dispose of the waste toner. Check the operation of the wastetoner bottle base. Disconnectand then connect J514 of the DC controller PCB. Replace thewaste toner case full sensor.Replace the DC controller PCB.Code Description Remedial action*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).**: model equipped with DADF-M1 (outside Japan: iR7086).