Chapter 22-20F-2-615) Mount the developing assembly locking plate [1].- 2 bosses [2]- 6 screws (TP; M4X6; black) [3]F-2-626) Slide out the 2 rails [1] of the pull-off unit.F-2-637) Remove the tape from the pull-off unit.8) Hold the pull-off unit [1] as follows, and hook the 4 holes [3] of the pull-off unit on the 4 protrusions [2] of the rail.F-2-649) Fix the extraction unit with the 2 screws (binding; M3X4) and push theextraction unit until it locks.F-2-6510) Fit the reuse band [1] in the hole [2] of the host machine.F-2-6611) Connect the connector [1].F-2-6712) Attach the connector cover [1].Check to be sure that the developing assembly locking plate is free of a gapand displacement, which are likely to cause image faults. (Especially, itmust not be riding over the bosses found below.)When mounting the developing assembly locking plate, take care not to trapthe cable [1].[1] [2][1][3] [3][2] [2][1][1][1][1][2][2][3][3][1][1] [2][1]