52D BD BFree-runFree-runD BD BFree-runFree-runD BFree-runFree-runD BD BClearClearClearClearHoldHoldHoldHoldFree-runFree-runEmergency stop ClearD BEmergency stop ClearFree-runD B0Setup value of SV.Pr67123456789Sequence at main power-off (SV.Pr67)Driving conditionduring deceleration after stallingContents of deviation counterDynamic BrakeThis driver is equipped with a dynamic brake for emergency stop.Pay a special attention to the followings.1. Dynamic brake is only for emergency stop.2. Dynamic brake is a short-duration rating, and designed for only emergency stop. Allow approx. 3 minutespause when the dynamic brake is activated during high-speed running.(Over-current protection (error code No. 14) may be activated when the dynamic brake circuit inside theF-frame driver has overheated.)• You can activate the dynamic brake in the following cases.1) When the main power is turned off2) At Servo-OFF3) When one of the protective function is activated.In the above cases from 1) to 3), you can select either activation of the dynamic brake or making themotor free-run during deceleration or after the stop, with parameter.Note that when the control power is off, the dynamic brake will be kept activated.1) Setup of driving condition from deceleration to after stop by main power-off (SV.Pr67)The motor becomes a dynamo when driven externally, and shorting current runswhile this dynamic brake is activated and might cause smoking or fire.Do not start/stop the motor by turning on/off the Servo-ON signal (SRV-ON).Or it may damage the dynamic brake circuit of the driver.Torque limit value at emergency stop will be that of SV.Pr6E (Emergency stop torque set up)when the setup value is 8 or 9.