121[Operation Setting]OperationSettingDetect the limit sensor in a direction of homing by 16.Pr30 (Homing speed (high)), decelerate and stop. Afterthat, get out of the limit sensor area once, detect the limit sensor turning off by 16.Pr31 (Homing speed (low))and define that point as a home position.(1) A starting point is at any place other than on the positive limit sensorL-SPDL-SPDH-SPDH-SPD(2) A starting point is on the positive limit sensorPositive directionlimit sensor Negative directionlimit sensorDirection of homingLimit SensorExample: An operation in a positive directionCaution1) If any of the set values of the parameters below is “0”, an operation trips due to homing error protection(error code No. 68) and stops according to an operation at alarm occurrence.• 16.Pr30 (Homing speed (high))• 16.Pr31 (Homing speed (low))• 16.Pr33 (Homing acceleration setting)• 16.Pr34 (Homing deceleration setting)2) Also, if the over-travel inhibit input is enabled in an operating direction under any of the conditions belowduring homing, an operation trips due to homing error protection (error code No. 68) and stops accordingto an operation at alarm occurrence.• After the reversal due to detection of a limit sensor in a direction of homing, a limit sensor in the reversedirection, not in a direction of homing, has been detected.How to decelerate at the detection of a limit sensor depends on the settings of SV.Pr55 (Over-travelinhibit input operation setting). (For a set value = 0 or 2, deceleration-and-stop. For a set value = 1 or 3,stop in the deceleration time “0”.)3) We would like to ask you to design so that a sensor signal does not vary (beyond the sensor signal width)when the motor is decelerating after it detects the limit sensor.4) In this system, delay time of a maximum of 2 ms is caused when detecting the limit sensor at the • partand, therefore, the home position varies to the extent of a maximum of homing speed (low) multiplied by2 (ms).DescriptionSpecify the high speed for the homing operation (0 to 6000 r/min).Specify the low speed for the homing operation (0 to 6000 r/min).Specify the offset operation speed if the home offset operation is performed (0 to 6000 r/min). For the homeoffset operation, refer to page 124.Specify the acceleration for the homing operation in a range between 0 to 3000 r/min.Specify the deceleration for the homing operation in a range between 3000 to 0 r/min.Specify an operating direction for the homing. (0: positive direction, 1: negative direction)Specify a type of homing. ([4]: Limit sensor)Specify whether or not to perform the home offset operation. (0: Not perform, 1: Perform) For the home offsetoperation, refer to page 124.Specify the home offset (–2147483647 to 2147483647 pulses). If the home offset is not required, specify “0”.16.Pr**32.Pr**303132333435363701Parameter number• Parameters related to this operation