913-7-3 Bar code/2D code object settings: BRFSets the conditions such as the position and size of the bar code/2D code as well as code characteristics.ンㄆㄇㄆㄓㄆㄏㄆ• If the object type set in the specified object number is not the bar code/2D code, the laser marker returns the negativeresponse.• To specify the module fill spacing of the bar codes, use WDC command (Line width / filling line spacing).• The laser power correction and the scan speed correction set by this command will not apply to the human readabletext.• With LP-400/V compatible command mode, you cannot set and readout the settings for PDF417, iQR code, QR code forChinese characters (GB/T 18284), and CODE93.⿎ Setting request data / response data for readoutStartcode BRF Subcommand[Object No.] [System reserved value][Code type] ... (vary depending on code type)(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode BRF R[Object No.]1-byte or2-byte (2D side of composite code)(Checksum) End code⿎ Data description1. When the code type is CODE39/ITF/NW-7Name(> Name in LP-400/V)Data length[byte] Data contents RemarksObject No.(> Bar code No.) 1 “0”–“7”: Object No. 1100 to 1107System reservedvalue(Area No.)1 “0”–“9”, “A”–“F” This value does not affect thesettings anymore.Code type 2“00”: CODE39“01”:ITF“03”: NW-7Invert 1 “0”: Do not invert“1”: InvertSet “0” to mark a bar, “1” to marka space.Check character(and Start/stopcharacter for NW-7)1For CODE39 and ITF“0”: Check character OFF“1”: Check character ON• For CODE39 and ITF, specifythe existence of checkcharacter.• For NW-7, select start and stopcharacters from A, B, C or Dand specify the existence ofcheck character.For NW-7“A”–“D”: Check character OFF“a”–“d”: Check character ONBar code height 7Model Setting range [mm]LP-GS051(-L) “000.050”–“055.000”LP-GS052 “000.050”–“030.000”LP-RC350S “000.050”–“085.000”LP-RF200PLP-RV200P “000.050”–“090.000”ME-LP-GS-SR-COMP-3