231-4-2 Communication settingsItem Ethernet communication settingsCommunication protocol TCP/IPStandards IEEE802.3 (10BASE-T) / IEEE802.3u (100BASE-TX)Applicable cable Category 5 or higherApplicable HUB (or rooter) 10BASE-T / 100BASE-TX compatibleIP address 1.0.0.0 to 223.255.255.255 * (Initial value: 192.168.1.5)Subnet mask 128.0.0.0 to 255.255.255.254 (Initial value: 255.255.255.0)Default gateway 1.0.0.0 to 223.255.255.255 * (Initial value: 0.0.0.0 (Unspecified))PC configuration software port 1025 to 65534, except 9090 (Initial value: 9093)Command communication port 1025 to 65534, except 9090 (Initial value: 9094)* Do not use “127” in the first octet.ンㄆㄇㄆㄓㄆㄏㄆ• The communication control of the laser marker through the Ethernet should be performed in a secure network settings.• Even the IP Address and Subnet Mask values are within the configurable range, they may not be available dependingon the combination.• For the details of the communication settings, refer to “1-1-3 Settings before external control” (P.14).⿎ Ethernet communication settings for communication command controlItem Ethernet communication settings (LP-400/V compatible mode)Start code • Setting request data, Readout request data, Response data for readout: STX• Positive response code: ACK• Negative response code: NAKResponse data command Included only in response data for readoutSub command • Setting request data: S• Readout request data: R• Response data for readout: ACharacter code ASCII codeEncoding for 2-bytecharactersShift-JIS codeCheck sum OFFEnd code CRReception timer Timeout monitoring ON (10 sec.)ME-LP-GS-SR-COMP-3