1123-9-2 Point radiation correction: PRFSpecifies the offset value of the position and laser power to the all points set in the selected object no.⿎ Setting request data / response data for readoutStartcode PRF Subcommand[Object. No.] [System reserved value][X-offset] [Y-offset] [Laser power correction][Pulse cycle correction]LP-GS / LP-RC: 22-byteLP-RF / LP-RV: 25-byte(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode PRF R [Object No.]2-byte(Checksum) End code⿎ Data descriptionName(> Name in LP-400/V)Data length[byte] Data content RemarksObject No.(> Point radiation No.) 2 “00”–“15”: Object No. 1400 to 1415System reserved value 1 “0”X-offset 8“-999.999”–“+999.999” [mm] Moves the all points set in the selectedobject no. from currently set position.Y-offset 8Laser power correction 3 “000”–“999” [%]• The correction ratio is calculatedusing the value of laser power foreach point as 100%.• When laser power correction ratiois set to “000”, all points set in thespecified point radiation no. are notscanned at lasing.Pulse cycle correction * (3) “001”–“999” [%]The correction ratio is calculated usingthe value set at the laser settings as100%.Total data length22or25Fixed length.• LP-GS / LP-RC series: 22-byte• LP-RF / LP-RV series: 25-byte* Only for LP-RF series and LP-RV series.⿎ Data exampleCondition: Object No. = 1, System reserved value = 0, X-offset = 0, Y-offset = -5.6, Laser power correction = 130,Pulse cycle correction = 100• Setting Transmission data [STX] PRF S 010+000.000-005.600130100 [CR]• Readout Transmission data [STX] PRF R 01 [CR]Response data [STX] PRF A 010+000.000-005.600130100 [CR]ME-LP-GS-SR-COMP-3