1303-12-4 Laser fine tune: WTCFine-tunes lasing quality such as starting and ending point by each file.⿎ Setting request dataStartcode WTC S[Starting point] [Ending point] [Corners] [Curve][Waiting time] [Pre-scan time] [Jump][System reserved value] [System reserved value]33-byte, 25-byte or 22-byte(Checksum) End code⿎ Readout request dataStartcode WTC R (Check sum) End code⿎ Response data for readoutStartcode WTC A[Starting point] [Ending point] [Corners] [Curve][Waiting time] [Pre-scan time] [Jump][System reserved value] [System reserved value]33-byte(Checksum) End code⿎ Data descriptionName Data length[byte] Data contents RemarksStarting point 4 “-100”–“+100”Ending point 4 “-100”–“+100”Corners 3 “000”–“100” • With a larger value, lasing time becomeslonger.• Jump and system reserved values can beomitted.• If the jump is omitted, omit the systemreserved values, too.• If the jump is omitted, the value set last (theinitial value if it was not set) is applied.Curve 3 “000”–“100”Waiting time 3 “000”–“100”Pre-scan time 5 “00.00”–“10.00” [ms]Jump * (3) “000”–“100”System reservedvalue * (4) “0.00”–“9.99”• These settings correspond to “pointradiation on wait” and “point radiation offwait” at LP-400/V series. These values donot affect the settings anymore.• It is not possible to omit one side of thesystem reserved values.System reservedvalue * (4) “0.00”–“9.99”Total data length33(25)(22)Fixed length.• When sending all data and response data for readout: 33-byte• When system reserved values are omitted: 25-byte• When jump and system reserved values are omitted: 22-byte* These items can be omitted.ME-LP-GS-SR-COMP-3