80⿎ Example of command settingsCondition: Counter No. = 0, Current value = 1234, Starting value = 0, End value = 9999, Step value = 1,Count timing = 8, Reset at date change = 1• Setting Transmission data [STX] CNT S 000123400000000999900000181 [CR]• Readout Transmission data [STX] CNT R 0 [CR]Response data [STX] CNT A 000123400000000999900000181 [CR]ンㄆㄇㄆㄓㄆㄏㄆ• If the counter is reset at date change during on-the-fly marking operation (single trigger mode), the marking trigger readystatus turns off momentary and there is a case that the next marking could not be executed due to Warning E751.• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot beset and readout.• With LP-400/V compatible command mode, the counter value larger than 999999 cannot be set and readout.3-6-2 Counter reset: CTRResets the current value to the starting value.⿎ Setting request dataStartcode CTR S[Counter 0] [Counter 1] [Counter 2] [Counter 3][Global counter 16] [Global counter 17][Global counter 18] [Global counter 19]8-byte(Checksum) End code⿎ Data descriptionName Data length[byte] Data contents RemarksCounter 0 1“0”: Do not reset“1”: ResetCounter 1 1Counter 2 1Counter 3 1Global counter 16 1Global counter 17 1Global counter 18 1Global counter 19 1Total data length 8 The data length is fixed.ンㄆㄇㄆㄓㄆㄏㄆ• The setting changed by this command is saved in the laser marker without overwriting to the file.• If the counter is reset during on-the-fly marking operation, the marking trigger ready status turns off momentary andthere is a case that the next marking could not be executed due to Warning E751.• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot bereset.⿎ Example of command settingsCondition: To reset counter 0 and 16• Setting Transmission data [STX] CTR S 10001000 [CR]ME-LP-GS-SR-COMP-3