783-5-5 Character object settings (shortened): SPCSets only X-/Y-position and laser power correction in the character object settings.ンㄆㄇㄆㄓㄆㄏㄆ• You can use this command as a shortened command consisting only of X-/Y-positions and laser power correction of thecharacter object settings (STC) command.• This command is applied to the character objects (reference list type).⿎ Setting request data / response data for readoutStartcode SPC Subcommand[Object No.] [X-position] [Y-position][Laser power correction]21-byte(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode SPC R [Object No.]2-byte(Checksum) End code⿎ Data descriptionName(> Name in LP-400/V)Data length[byte] Data contents RemarksObject No.(> Character condition No.) 2 “01”–“60”: Object No. 1001 to1060X-position 8“-999.999”–“+999.999” [mm] Specifies the origin coordinate ofcharacter strings.Y-position 8Laser power correction 3 “000”–“999” [%]The correction ratio is calculated usingthe value set at the laser settings as100%.Total data length 21 Fixed length.⿎ Example of command settingsCondition: Object No. = 01, X-position = 15, Y-position = -10, Laser power correction = 80• Setting Transmission data [STX] SPC S 01+015.000-010.000080 [CR]• Readout Transmission data [STX] SPC R 01 [CR]Response data [STX] SPC A 01+015.000-010.000080 [CR]ME-LP-GS-SR-COMP-3