613-3-6 Guide laser: GIDSupported model: LP-GS051(-L) type / LP-RC350S / LP-RF series / LP-RV seriesControls radiation of red guide laser for marking position confirmation.⿎ Setting request dataStartcode GID S [Guide laser display]1-byte(Checksum)Endcode⿎ Data descriptionName Data length[byte]Data contents(> Name in LP-400/V) RemarksGuide laserdisplay 1“0”: Stop display“1”: Marking field“2”: Marking image(> Marking character)“3”: Work distance(> Dual pointer)“1” to “3” can be used only when the shutter isclosed.Total data length 1 The data length is fixed.ンㄆㄇㄆㄓㄆㄏㄆ• To radiate the guide laser with this command, set the guide laser display control method to “communication commands”by Laser Marker NAVI smart.• You can start the guide laser radiation only with the internal shutter closed.• The guide laser stops automatically after about one minute has passed from the startup.• When on-the-fly marking is set for LP-RC/LP-RF/LP-RV series, the guide laser of the marking image operates with theon-the-fly behavior.• For LP-GS052 type, guide laser command (GID) cannot be used.• Do not execute any other operation including the shutter opening/closing and sending MKM command while the guidelaser is emitted.• At LP-400/V compatible command mode “masked objects” is not available to the guide laser display.• At LP-400/V compatible command mode, the guide laser scan speed and guide laser Z-movement cannot be specified.For them, the settings used at the last operation of the guide laser are applied.⿎ Example of command settingsCondition: Guide laser display = 1• Setting Transmission data [STX] GID S 1 [CR]ME-LP-GS-SR-COMP-3