70⿎ Example of command settingsCondition: String No. = 51, Marking character = abcd• Setting Transmission data [STX] MCS S 51abcd [CR]• Readout Transmission data [STX] MCS R 51 [CR]Response data [STX] MCS A 51abcd [CR]3-5-2 Character entry (by ASCII and Shift-JIS code): STRSets the characters of the character objects (reference list type). Characters including alpha-numeric, functional charactersand Japanese characters are available.⿎ Setting request data / response data for readoutStartcode STR Subcommand[String No.] [Marking character]Max. 62-byte(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode STR R [String No.]2-byte(Checksum) End code⿎ Data descriptionName Data length[byte] Data contents RemarksString No. 2“01”–“50”: string No. 1 to 50 (for currentfile)“51”–“60”: string No. 101 to 110 (for allfiles)• Select the string No. of the referencelist to set characters.• You can use the strings No. 101 to110 commonly to all files.Marking character Min. 0Max. 60Input Method: ASCII code or Shift JIScode (can be mixed)• Use the ASCII code to specifyfunctional characters.• Use the Shift JIS code to specifytwo-byte characters (double bytecharacters).• For the characters that can bespecified in ASCII code, you can useboth ASCII code and Shift-JIS code.• Specify 0-byte for data length todelete characters.• For response data for readout, allcharacters except the functionalcharacters are readout in 2-bytecharacters (Shift-JIS code) regardlessthe settings.Total data length Max. 62 Variable length.ME-LP-GS-SR-COMP-3