114⿎ Example of command settingsCondition: X-movement = 10, Y-movement = -5.5, Rotation movement = 120,Number of overwritings = 2, Overwriting interval = 0.5,Y-axis mirroring = 0, X-axis mirroring = 1, Proportional type = 1• Setting Transmission data [STX] ALC S +010.000-005.500+120.00020.5011 [CR]• Readout Transmission data [STX] ALC R [CR]Response data [STX] ALC A +010.000-005.500+120.00020.5011 [CR]3-10-2 External offset settings: OFCSets the I/O input method for “External Offset Function” to adjust the marking position for the entire marking data in the file.⿎ Setting request data / response data for readoutStartcode OFC Subcommand[Input method]1-byte (Check sum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode OFC R (Check sum) End code⿎ Data descriptionName Data length[byte] Data contents RemarksInput method 1“0”: OFF“1”: Low 4-bit“2”: Low 8-bitIt is the input method (I/O or communicationcommand) of the offset value.Total data length 1 The data length is fixed.ンㄆㄇㄆㄓㄆㄏㄆ• Characters specified by SIN command and external offset function with I/O cannot be set together in one file.• External offset function cannot be used with on-the-fly marking at regular intervals or on-the-fly marking with multipletriggers.• At LP-400/V compatible command mode, “Low 10-bit” and “SEO command” of the input method cannot be set andreadout.⿎ Example of command settingsCondition: Input method = 2• Setting Transmission data [STX] OFC S 2 [CR]• Readout Transmission data [STX] OFC R [CR]Response data [STX] OFC A 2 [CR]ME-LP-GS-SR-COMP-3