124⿎ Example of command settingsCondition: Moving direction = 2, Line speed control = 1, Trigger mode = 0• Setting Transmission data [STX] TRG S 210 [CR]• Readout Transmission data [STX] TRG R [CR]Response data [STX] TRG A 210 [CR]3-11-2 Encoder resolution: ENCSupported model: LP-RC series / LP-RF series / LP-RV seriesSets the encoder resolution value used for the on-the-fly marking. This setting is applied to all marking files.⿎ Setting request data / response data for readoutStartcode ENC Subcommand[Encoder resolution]6-byte(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode ENC R (Check sum) End code⿎ Data descriptionName Data length[byte] Data contents RemarksEncoder resolution 6 “005.00”–“600.00” [pulses/mm] Only when line speed control is set to“encoder input”, set this value.Total data length 6 Fixed length.ンㄆㄇㄆㄓㄆㄏㄆ• The setting changed by this command is saved in the laser marker without overwriting to the file.⿎ Example of command settingsCondition: Encoder resolution = 120.5• Setting Transmission data [STX] ENC S 120.50 [CR]• Readout Transmission data [STX] ENC R [CR]Response data [STX] ENC A 120.50 [CR]ME-LP-GS-SR-COMP-3