1353-14-2 Command mode: RSMSwitches the command mode between LP-400/LP-V compatible mode and the standard one. This command is availablewhen LP-400/V compatibility setting is enabled in system settings.⿎ Setting request data / response data for readoutStartcode RSM Subcommand[Command mode]1-byte(Checksum) End codeSub command is “S” for the setting request data and “A” for the response data for readout.⿎ Readout request dataStartcode RSM R (Check sum) End code⿎ Data descriptionName Data length [byte] Data contents RemarksCommand mode 1 “0”: LP-400/V command mode“1”: Standard command modeTotal data length 1 The data length is fixed.ンㄆㄇㄆㄓㄆㄏㄆ• This command is available only when “LP-400/V compatibility” is enabled in system settings of Laser Marker NAVIsmart.• When “LP-400/V compatibility” is enabled in system settings of Laser Marker NAVI smart, the command mode is always“LP-400/V command mode” at the time of starting the remote control mode. To use standard command mode, alwayssend this command at first or disable “LP-400/V compatibility” in system settings.• To switch the command mode from “LP-400/V command mode” to “standard command mode” by RSM command, thecommunication format (start code, sub-command and etc.) of the setting request data should be followed by LP-400/V compatible format. The response data to this setting request is returned also in LP-400/V compatible format. Thestandard command format is applied afterward.• The setting by this command is not saved in the laser marker.⿎ Example of command settingsCondition: Command mode = 1• Setting Transmission data [STX] RSM S 1 [CR]• Readout Transmission data [STX] RSM R [CR]Response data [STX] RSM A 1 [CR]ME-LP-GS-SR-COMP-3