77Name(> Name in LP-400/V)Data length[byte] Data contents RemarksCharacter spacingangle 7 “-180.00”–“+180.00” [°]With LP-400/V compatible commandmode, the character spacing type ofthe arc is always set to “fixed spacing”.Font No. 1 “1”–“9”With LP-400/V compatible commandmode, the fonts from No. 10 cannot beset and readout.Bold line width 5 “0.000”–“6.000” [mm]• If you do not make characters bold,set 0.000.• If you make characters bold, set thebold line width to 1/2 or less of thecharacter height or width, whicheveris smaller.Laser powercorrection 3 “000”–“999” [%]The correction ratio is calculated usingthe value set at the laser settings as100%.Scan speedcorrection 3 “001”–“999” [%]Pulse cyclecorrection * (3) “001”–“999” [%]Total data length80or83The data length is fixed.• LP-GS/LP-RC series: 80-byte• LP-RF/LP-RV series: 83-byte* Only for LP-RF series and LP-RV series.⿎ Example of command settingsCondition: When the character arrangement is straight lineObject No. = 01, System reserved value = 0, First string No. to apply = 01, Last string No. to apply = 03,Character spacing type = 0, Horizontal and vertical alignment = 0,Character height = 4.5, Character width = 4, X-position = -10, Y-position = 2.5,Character spacing = 4.2, Linefeed spacing = 5, Rotation angle = -180,Font No. = 2, Bold line width = 0.3, Laser power correction = 120,Scan speed correction = 80, Pulse cycle correction = 100• Setting Transmission data [STX] STC S 010010300004.500004.000-010.000+002.500004.200005.000-180.0020.300120080100 [CR]• Readout Transmission data [STX] STC R 01 [CR]Response data [STX] STC A 010010300004.500004.000-010.000+002.500004.200005.000-180.0020.300120080100 [CR]ME-LP-GS-SR-COMP-3