1612. If you want to use standard command mode, specify the communication command format on the“Command format” panel.• Start code: STX (initial setting) / None• Include command in response: ON (initial setting) / OFF• Sub-command for response data: Any single byte characterof ASCII code from 01(HEX) to 7F(HEX) can be specified.• Initial setting of positive response code: A• Initial setting of negative response code: E• Initial setting of read request response code: A• Encoding for 2-byte characters: Shift-JIS (initial setting) / GB2312• Input method for control codesンㄆㄇㄆㄓㄆㄏㄆ• The command format settings here are applied to the standardcommunication format and not applied to LP-400/LP-V compatibleformat. For the details of the standard command format, refer to the “Serial Communication Command Guide”.• For the command format of LP-400/V compatible mode, refer to “2-3 Communication Data Format” (P.31).13. Click “Set” on the lower right corner of the screen.14. Disconnect the online connection with the laser marker.15. Turn OFF the laser marker power and wait for five seconds or more, then restart.The configured items will be reflected to the laser marker.ワㄐㄕㄊㄆ• Do not turn the laser marker power OFF while being connected to online.16. The control by the external device starts by switching the laser marker to the remote mode.ンㄆㄇㄆㄓㄆㄏㄆ• For the details of the System settings, refer to “Laser Marker NAVI smart Operation Manual”.ME-LP-GS-SR-COMP-3