111⿎ Readout request dataStartcode PRD R [Object No.] [Point No.]5-byte(Checksum) End code⿎ Response data for readoutStartcode PRD A[Object No.] [Point No.] [Radiation time][Laser power correction] [X-position] [Y-position]31-byte or 5-byte(Checksum) End code⿎ Data descriptionName(> Name in LP-400/V)Data length[byte] Data content RemarksObject No.(> Point radiation No.) 2 “00”–“15”: Object No. 1400 to 1415Point No. 3 “000”–“049”Reads out the point radiation setting by apoint.It is not possible to readout settings for themultiple points at once.Radiation time 7 “00000.1”–“99999.9” [ms]• If there is no setting in the specifiedpoint no., these items are not includedin the response data for readout.• The correction ratio of laser power iscalculated using the value set at thelaser settings as 100%.Laser powercorrection 3 “000”–“999” [%]X-position 8“-999.999”–“+999.999” [mm]Y-position 8Total data length31or5The response data length is fixed.• When the specified point no. has settings : 31-byte• When the specified point no. has no settings : 5-byte⿎ Data exampleCondition: Object No. = 1, Point No. = 5, Radiation time = 2000,Laser power correction = 100, X-position = 25.5, Y-position = -7• Readout Transmission data [STX] PRD R 01005 [CR]Response data [STX] PRD A 0100502000.0100+025.500-007.000 [CR]ンㄆㄇㄆㄓㄆㄏㄆ• If the unit of the radiation time is set to other than [ms], you cannot readout these settings by LP-400/V compatiblecommand mode.ME-LP-GS-SR-COMP-3