73⿎ Timing chart for SIN command transmissionEx. When “Characters specified by SIN command” is set to string No. 0 and 1T2T1OFF (Close)ON (Open)ONONONOFFOFFOFFONOFFONOFFSINS00a SINS01b SINS00c SINS01dACK ACKACK ACKPROCESSING OUT (Y10)READY OUT (Y5)TRIGGER IN (X5)LASER STANDBY OUT (Y6)SHUTTER OPEN 1,2 OUT (Y8, Y9) *1SHUTTER OPEN OUT (No.39) *2DATA WAIT OUT (No.38) *2SIN commandResponse data*1 : LP-GS series only*2 : LP-RF/LP-RC/LP-RV series onlyItem Time RemarksT1 0 ms or more Before sending SIN command, confirm that the shutter is opened.For LP-RC/LP-RF/LP-RV series, you can use either SHUTTER OPEN OUT signal orDATA WAIT OUT (No.38) to know the timing of SIN command input.T2 0 ms or more After confirming PROCESSING OUT (Y10) is turned ON, the next SIN command datacan be sent.For LP-RC/LP-RF/LP-RV series, you can use either PROCESSING OUT signal or DATAWAIT OUT (No.38) to know the timing of SIN command input.ンㄆㄇㄆㄓㄆㄏㄆ• SIN command can be accepted only when the shutter is open. The shutter status can be confirmed by using SHUTTEROPEN OUT signal of I/O.• When “command reception permission ON” is set by MKM command, SIN command can not be accepted.• When SIN command will be sent right after file change (FNO/FNN command) or command reception permission OFF(MKM command) setting, set the wait time of 1 second or more after FNO/FNN/MKM command reception.• For LP-RC/LP-RF/LP-RV series, you can know the timing of SIN command input by confirming DATA WAIT OUT (No.38)signal of I/O connector is ON.• When the file with “Characters specified by SIN command” function is selected, transmit this command by every markingtriggers. Otherwise marking trigger ready does not turn ON, and marking is not available.• It is not possible to send SIN command twice or more to one string number for one marking trigger.• To reset the transmitted SIN command data, either close the shutter, or set “command reception permission ON” forMKM command.ME-LP-GS-SR-COMP-3