109⿎ Data exampleCondition: Object No. = 1, Point No. = 5, Radiation time = 2000, Laser power correction = 100,X-position = 25.5, Y-position = -7• Setting Transmission data [STX] PRD S 0100502000.0100+025.500-007.000 [CR]Condition: When setting 4 points:Object No. = 1, Point No. = 0, Radiation time = 2000, Laser power correction = 100,X-position = 25.5, Y-position = 7, X-position = 25.5, Y-position = -7,X-position = -25.5, Y-position = -7, X-position = -25.5, Y-position = 7• Setting Transmission data [STX] PRD S 0100002000.0100+025.500+007.000+025.500-007.000-025.500-007.000-025.500+007.000 [CR]⿎ Setting request data : When specifying radiation time and laser power correction ratio foreach pointStartcode PRD S[Object No.] [Point No.][Radiation time] [Laser power correction]15-byte(Checksum) End code⿎ Data descriptionName(> Name in LP-400/V)Data length[byte] Data content RemarksObject No.(> Point radiation No.) 2 “00”–“15”: Object No. 1400 to 1415Point No. 3 “000”–“049”Specifies the radiation time and laserpower correction ratio by a point.It is not possible to specify the radiationtime and laser power correction ratio forthe multiple points at once.Radiation time 7 “00000.1”–“99999.9” [ms] The unit of the radiation time is always [ms].Laser powercorrection 3 “000”–“999” [%] The correction ratio is calculated using thevalue set at the laser settings as 100%.Total data length 15 Fixed-length data.⿎ Data exampleCondition: Object No. = 1, Point No. = 3, Radiation time = 2000, Laser power correction = 100• Setting Transmission data [STX] PRD S 0100302000.0100 [CR]ME-LP-GS-SR-COMP-3