188Available commands are listed below.S Set whether the power supply is enabled or disabled.Press "S." The command prompt changes to "Select port number to bechanged>." Enter the port number for which you wish to change the setting.Press "0" to change the settings of all ports at a time. Then, the commandprompt changes to "Up or Down PoE port admin status (U/D)>." Press "U" toenable power supply (Up). Press "D" to disable it (Down). When you completethe setting change, the display on the screen is automatically updated.I Set the power supply priority.Press "I." The command prompt changes to "Select port number to bechanged>." Enter the port number for which you wish to change the setting.Press "0" to change the settings of all ports at a time. Then, the commandprompt changes to "Enter the selection >." Press "1" for "Critical." Press "2" for"High." Press "3" for "Low." When you complete the setting change, the displayon the screen is automatically updated.L Set the upper limit of supplied power.Press "L." The command prompt changes to "Select port number to bechanged>." Enter the port number for which you wish to change the setting.Press "0" to change the settings of all ports at a time. Then, the commandprompt changes to "Enter the power limit>." Enter the limit between 3000 and15400 mW (in units of 200 mW). When you complete the setting change, thedisplay on the screen is automatically updated.Q Return to the previous menu.