97 With “allow to stop halfway” settingWhen the trigger mode is set to “continuous trigger” in the file settings, lasing operation is repeated while TRIGGER IN (X5)is on. With “allow to stop halfway” setting, the lasing operation is terminated immediately when TRIGGER IN turns OFF.T2T4T3T3T6T5T2T1READY OUT (Y5)TRIGGER IN (X5)PROCESSING OUT(Y10)PROCESSING ENDOUT (Y11)PROCESSING FAILOUT (Y12)ALARM OUT (Y15)ONOFFONOFFONOFFONOFFONOFFON (Normal)OFF (Error)ONOFFMarkinginterruptionLASING OUT (Y20)Item Time RemarksT1 2 ms or more Keep the ON status for the duration of repeating the lasing operation.T2 0 to 9999 ms When the trigger delay time is set in the selected file, trigger processing (lasing) operationstarts after the delay time.T3 0.0 to 60.0 sec. When the scanning interval is set, the next lasing operation starts after a lapse of thesetting period.T4 2 to 510 ms This is the output to notify that the marking trigger processing completed normally. Thisis One-shot output. Set the output time on the system settings screen. There is a smallmargin of error for the setting value.When the marking operation stops halfway because TRIGGER IN turns OFF, it is treatedas normal operation end.T5 ― Time for marking data creation. It varies depending on the quantity of the setting data. Thistime is required at every marking.T6 2 to 510 ms If the trigger processing was stopped by an alarm or a warning, PROCESSING FAIL OUT(Y12) turns on during the one-shot output period. PROCESSING END OUT (Y11) will notbe output at this time.ンㄆㄇㄆㄓㄆㄏㄆ• If the executed number of lasing operation are less than the specified minimum number, warning E630 occurs after themarking operation.• If TRIGGER IN signal remains ON though the executed number of lasing operation reaches the specified maximumnumber, warning E631 occurs and the subsequent lasing is canceled.ME-LPGS-SM-8