1457-2-3 Air filterThe air filter is placed in the air-cooling intake vent of this product. (1 filter on the controller, 1 filter on the head) Effect from deteriorationThe air filter soiled with dust may reduce the cooling effect of the air-cooling fan. This may cause the marking performanceto degrade, or failure of the laser marker. Replacement interval• There is a broken part, or contamination that cannot be removed by cleaning. Models of replacement partsFor details of purchasing air filters, please contact our sales agency.Part name Model RemarksDedicated air filters (set of 2 pcs.) LP-AFT70 The same air filter is used for both the head and the controller. Steps for cleaning (Daily maintenance) and replacement of air filterClean air filters regularly according to the usage environment.1. Turn OFF the key switch of the controller, anddisconnect the AC power cable.2. Loosen the screws of front panel at 2positions, and remove them.3. Remove the filter.One filter for head and controller each4. Clean the filter with neutral detergent and air-dry it.5. Attach the dried filter onto the front panel,and tighten it with the screws.Tightening torque: 0.3 N·mワㄐㄕㄊㄆ• Do not attach the filter when it is wet. This may cause the cooling capacity to degrade, or failure of the laser marker.• Do not operate the laser marker without the filters. It may cause a product failure.ME-LPGS-SM-8