1296-1-7 Code reader (LP-ABR) settingTo use the code reader LP-ABR series for the code checking of image checking after marking, set the followings by usingConfigurator LP-ABR software.• Set the code reading parameters of LP-ABR such as the code type and inversion to read the marked code symbolswithout errors.• Set the following communication and LAN settings for LP-ABR series:Category Item SettingsCommon - Communication Select Port Set “LAN” or “RS-232C/LAN”.Common - LAN IP Address Specify the same settings with “Image checking aftermarking” parameters in the system settings of the lasermarker.Data Port NoSubnet Mask Configure the communication settings according to thenetwork settings. Usually the code reader and the lasermarker are used on the same network.Default Gatewayンㄆㄇㄆㄓㄆㄏㄆ• For specifications and setting of the code reader LP-ABR series, refer to the instruction manuals for LP-ABR andConfigurator LP-ABR.6-1-8 Code reader (DataMan) settingIf DataMan is used for code checking of image checking after marking, set the following items.• DataMan IP address and Telnet Port number: Set them according to the network settings.• Code reading setting: Set the code type, etc. to read the code to be marked by the laser marker.ンㄆㄇㄆㄓㄆㄏㄆ• For specifications and setting of code reader DataMan, refer to the instruction manual for DataMan.• Ensure that any code other than the readout target is in the DataMan shooting range. Code reading is not performedproperly.• If the code type is UPC-E (6-digits UPC code), set DataMan’s “UPC/EAN Properties” as follows:• Check off “Expanded”• Check on “Delete Leading Zero” DataMan communication settings specification for connection with laser markerItem Ethernet communication specificationsCommunication protocol TCP/IPME-LPGS-SM-8