1054-6-13 Laser stop 2 inputIf LASER STOP 2 IN is released, the laser pumping is turned off and the shutter is closed, regardless of whether or not thelaser is radiating. Refer to “Laser marker operation when functions for safety measures are input” (P.77).TRIGGER IN (X5)ALARM RESET IN (X15)LASER STOP 2 IN (X11)LASER STANDBY OUT (Y6)PROCESSING OUT (Y10)PROCESSING END OUT (Y11)PROCESSING FAIL OUT (Y12)ALARM OUT (Y15)SHUTTER OPEN 1 OUT (Y8)SHUTTER OPEN 2 OUT (Y9)SHUTTER ENABLE IN (X9)SHUTTER IN (X8)LASER SUPPLY IN (X6)READY OUT (Y5)ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFON (Close)OFF (Open)ON (Open)OFF (Close)ON (Normal)OFF (Error)T2T1 T1 T1 T1T2T6T3T4 T4T3T5MarkinginterruptionItem Time RemarksT1 Max. 1 sec. There is a delay time of around 200ms to max. 1 second from turning ON/OFF ofSHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTEROPEN 2 OUT (Y9).SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output by the sameoperation, but their output timing has a margin of error.T2 100ms or more Keep the ON status for 100ms or more.T3 Approx. 8 to 15 sec. Time for completion of laser pumping.• Normal: Approx. 8 sec.• Re-pumping right after turning the laser pumping off: Approx. 15 sec.T4 ― Total time for shutter opening and marking data creation, or time for laser pumping,whichever is longer.T5 2ms or more Keep the ON status for 2ms or more.T6 2 to 510ms This is One-shot output. Set the output time on the environment setting screen. There isa small margin of error for the setting value.ME-LPGS-SM-8