1064-6-14 Interlock inputIf INTERLOCK (X16 - X17 and X18 - X19) is opened, the laser pumping is turned off and the shutter is closed, regardless ofwhether or not the laser is radiating. Refer to “Laser marker operation when functions for safety measures are input” (P.77).T3T1T1 T1T1T1 T1T2 T2 T2 T2 T2 T2T3T3T5 T5 T5T7T4 T4 T4T6TRIGGER IN (X5)INTERLOCK 1 (X16-X17)INTERLOCK 2 (X18-X19)INTERLOCK 1 MONITOR(Y16-Y17)ALARM RESET IN (X15)SHUTTER OPEN 1 OUT (Y8)SHUTTER OPEN 2 OUT (Y9)READY OUT (Y5)PROCESSING OUT (Y10)PROCESSING END OUT (Y11)PROCESSING FAIL OUT (Y12)ALARM OUT (Y15)INTERLOCK 2 MONITOR(Y18-Y19)SHUTTER ENABLE IN (X9)SHUTTER IN (X8)LASER SUPPLY IN (X6)LASER STANDBY OUT (Y6)ON (Open)OFF (Close)ON (Normal)OFF (Error)ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFCLOSEOPENCLOSEOPENCLOSEOPENCLOSEOPENONOFFMarkinginterruptionItem Time RemarksT1 Approx. 20ms INTERLOCK MONITOR is switched open and closed with a delay of approx. 20ms withreference to each INTERLOCK input.T2 Max. 1 sec. There is a delay time of around 200ms to max. 1 second from turning ON/OFF ofSHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTEROPEN 2 OUT (Y9). SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be outputby the same operation, but their output timing has a margin of error.T3 100ms or more Keep the ON status for 100ms or more.T4 Approx. 8 to 15 sec. Time for completion of laser pumping.• Normal: Approx. 8 sec.• Re-pumping right after turning the laser pumping off: Approx. 15 sec.T5 ― Total time for shutter opening and marking data creation, or time for laser pumping,whichever is longer.T6 2ms or more Keep the ON status for 2ms or more.T7 2 to 510ms This is One-shot output. Set the output time on the environment setting screen. There isa small margin of error for the setting value.ME-LPGS-SM-8